The ABB S271-K0.5A Miniature Circuit Breaker is a single-pole, DIN-rail mounted protection device from the System pro M S 270 series. It features a K-curve tripping characteristic with a 0.5 A rated current and 230/400 V AC rated voltage. Designed for cable and appliance protection, it provides thermal and magnetic trip mechanisms with a rated short-circuit breaking capacity of 6 kA in accordance with EN 60 898.
The Fluke i1010 is an AC/DC current clamp designed for use with digital multimeters. It measures currents from 1 A up to 1000 A DC and up to 600 A AC using a Hall-effect sensor. The clamp outputs 1 mV per amp for direct reading on compatible meters.
AEMC JM830A AC Current Probe — 3000A range, 0.333mA/A output, low phase shift, banana plug lead — Ideal for DMMs, power, and harmonic meters.
The Amprobe MO-100 Milliohm Meter offers accurate four-terminal resistance measurement with auto-hold, overvoltage protection, and a portable battery-powered design.
Fluke i200 AC current clamp enables accurate 0.5–200A AC measurements using a multimeter. Features 1 mA/A output, banana plug interface, and CAT III 600V safety for electrical testing.
3 5/6 digits 5999 counts 0.5% best accuracy Dual display with analog bargraph Auto/Manual ranging USB data upload Measurement Range DC Voltage (DCV) 600m/6/60/600V ±(0.5%+4d), 1000V ±(1.0%+6d) AC Voltage (ACV) 6/60/600V ±(0.8%+10d), 750V ±(1.0%+10d) DC Current (DCA) 600μ/6000μA ±(1.0%+10d), 60m/600mA ±(1.0%+10d), 6/10A ±(1.2%+10d) AC Current (ACA) 600μ/6000μA ±(1.5%+10d), 60m/600mA ±(1.5%+10d), 6/10A ±(2.0%+15d) Resistance 600Ω ±(0.8%+5d), 6k/60k/600k/6MΩ ±(0.8%+4d), 60MΩ ±(1.2%+10d) Frequency 100/1000Hz ±(0.5%+4d), 10k/100kHz ±(0.5%+4d), 1M/30MHz ±(0.5%+4d) Capacitance 40nF±(5%+30d), 400n/4μ/40μF±(3.5%+8d) 200μF±(5.0%+10d) Temperature -20~400˚C(0~750˚F) ±(1.0%+5d), 400~1000˚C(750~1832˚F) ±(1.5%+15d) Continuity with Buzzer Yes Diode Test Yes Transistor Test Yes Power Source AAA(1.5V)×2pcs (Not included)
AEMC MR416 Dual Range Probe: Hall effect AC/DC probe with 40A/400A & 60A/600A ranges, 10mV/A & 1mV/A output, 4mm plugs, USB or battery powered.
AEMC MN72 Current Probe designed for Model 6424, enables accurate ground & bond testing with one-button operation, CAT IV 600V safety, and IP65 rating.
The AEMC SR601 AC Current Probe delivers 1000 A AC current measurement with a 1000:1 ratio, 1 mA/A output, and 4 mm banana jack connection for DMMs, loggers, and compatible instruments.
Complies with CE safety standard 3 1/2 digits 1999 counts Palm size for easy storage and carrying Digits 3 1/2 digits 1999 counts Accuracy 0.5% best accuracy DCV 2200m/2000m/20/200V ±(0.8%+3d), 500V ±(1.0%+3d) ACV 200/500V ±(1.2%+5d) DCA 2000u/20m/200mA ±(1.2%+5d), 10A ±(2.5%+5d) ACA 400μA/4000μA ±(1.5%+10d), 40mA/400mA ±(1.5%+10d), 10A ±(2.5%+15d) Resistance 200Ω ±(1.5%+5d) , 2000/20k/200kΩ ±(1.0%+3d) , 20MΩ ±(1.0%+5d), 200MΩ ±(1.0%(rdg-l0)+10d) Temperature -40~150˚C ±(1.0%+3d), 150-1000˚C ±(1.5%+15d)-40~302˚F(1.0%+4d), 302-1832˚F ±(1.5%+15d) Power source 1.5V AAA x 2 (not included) Accessories Test leads Square signal output 50Hz (5 Vp-p, 50KΩ)
Boost energy efficiency with the Fluke 1735 Power Logger! Perfect for three-phase load studies & electrical troubleshooting. Learn more and optimize your systems today!Â
The Fluke i400s AC Current Clamp extends current measurement capability for multimeters, power quality analyzers, and oscilloscopes. It supports AC current ranges from 0.5 A to 400 A with dual output scaling and a compact clamp design rated for CAT IV 600 V environments.
The AEMC 6416 Clamp-On Ground Resistance Tester offers fast, accurate ground resistance measurements without disconnecting the system. This product includes an alarm, memory and an easy clamp-on operation, making it ideal for professionals needing reliable earth ground testing with convenience and safety.
AEMC MN251T AC Current Probe: 200A range, 1mV/A output, 10ft BNC lead—ideal for DMMs and voltage-input instruments needing accurate current readings.
AEMC SR651 AC Current Probe: Measures up to 1000A with 1mV/A output, banana jack connectors, low phase shift, ideal for power and harmonic meters.
The Fluke i1010 AC/DC current clamp kit extends the current measurement range of compatible multimeters. It measures AC current from 1 A to 600 A and DC current from 1 A to 1000 A using a Hall-effect sensor. The kit includes a zippered carrying case for storage and transport.
High-accuracy AEMC SR604 AC current probe with 1000A range, low phase shift, 1mA/A output, 5 ft lead, ideal for DMMs, loggers, oscilloscopes, and power measurements.
ACV True-RMS Auto Range Pocket Size 3-3/4 digits 3999 counts DCV 400mV, 4/40/400V ±(0.5%+4d), 600V ±(1%+4d) ACV 400mV±(1.5%+6d), 4/40/400V ±(0.8%+6d), 600V ±(1.0%+6d) Resistance 400Ω ±(0.8%+5d) 4k/40k/400k/4MΩ ±(0.8%+4d), 40MΩ ±(1.2%+5d) Frequency 100/1000Hz/10k/100k/1MHz/10MHz ±(0.5%+4d) Capacitance 4nF ±(5%+40d), 40n/400n/4μ/40μ ±(3.5%+8d), 2000μF ±(5%+8d) Duty cycle 0.1~99.9% ±(0.5%+4d) Continuity with beeper 50 ±30Ω Diode test Range: 0 ~ 1.5V Resolution: 1mV Power source 2 x 1.5V AAA battery (Not included)
AEMC 2135.59 ground resistance tester kit delivers 3P ground resistance, 2P resistance, AC/DC voltage, and AC current measurement with MN72 probe support.
AEMC 2135.58 Model 6424 Ground Resistance Tester delivers digital 3-point and 2-point ground resistance testing with AC/DC voltage measurement and auto-ranging operation.
The INNO Instrument SPA3200 is a 3-channel digital power meter built for precise power consumption testing in R&D, automated assembly lines, and power test benches. It combines high measurement accuracy, a wide direct-input range, real-time waveform display, harmonic analysis, and internal data storage in a compact semi-rack design.
AEMC 2135.71 AC Current Probe delivers MN82 current measurement for AEMC 6471/6472 ground resistance testing, including selective and stakeless ground electrode workflows.
AEMC JM810A AC Current Probe — 2000A Range, 1mA/A Output, Low Phase Shift, Banana Plug Lead — Ideal for DMMs, Power, and Harmonic Meters
AEMC MR417 Probe: Dual range AC/DC hall effect probe for oscilloscopes, 40A/400A & 60A/600A, BNC output, USB/battery power, auto zero adjust.
AEMC MR526 Dual Range Probe: AC/DC hall effect probe with 100A/1000A & 150A/1400A ranges, 10mV/A & 1mV/A output, 4mm banana plugs, USB or battery power.