JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
Try searching for keywords in categories, brands, products, and more. If you have any questions, please contact our Support team
Out of stock
Shopping cart
Your cart is empty
Looks like you haven't made your choice yet.
x
SKU:
Subtotal:
Total:
My Quote
Your Quote is empty
Checkout using your account
This form is protected by reCAPTCHA - the Google Privacy Policy and Terms of Service apply.
Checkout as a new customer
Creating an account has many benefits:
3 5/6 digits 5999 counts 0.5% best accuracy Dual display with analog bargraph Auto/Manual ranging USB data upload Measurement Range DC Voltage (DCV) 600m/6/60/600V ±(0.5%+4d), 1000V ±(1.0%+6d) AC Voltage (ACV) 6/60/600V ±(0.8%+10d), 750V ±(1.0%+10d) DC Current (DCA) 600μ/6000μA ±(1.0%+10d), 60m/600mA ±(1.0%+10d), 6/10A ±(1.2%+10d) AC Current (ACA) 600μ/6000μA ±(1.5%+10d), 60m/600mA ±(1.5%+10d), 6/10A ±(2.0%+15d) Resistance 600Ω ±(0.8%+5d), 6k/60k/600k/6MΩ ±(0.8%+4d), 60MΩ ±(1.2%+10d) Frequency 100/1000Hz ±(0.5%+4d), 10k/100kHz ±(0.5%+4d), 1M/30MHz ±(0.5%+4d) Capacitance 40nF±(5%+30d), 400n/4μ/40μF±(3.5%+8d) 200μF±(5.0%+10d) Temperature -20~400˚C(0~750˚F) ±(1.0%+5d), 400~1000˚C(750~1832˚F) ±(1.5%+15d) Continuity with Buzzer Yes Diode Test Yes Transistor Test Yes Power Source AAA(1.5V)×2pcs (Not included)
Complies with CE safety standard 3 1/2 digits 1999 counts Palm size for easy storage and carrying Digits 3 1/2 digits 1999 counts Accuracy 0.5% best accuracy DCV 2200m/2000m/20/200V ±(0.8%+3d), 500V ±(1.0%+3d) ACV 200/500V ±(1.2%+5d) DCA 2000u/20m/200mA ±(1.2%+5d), 10A ±(2.5%+5d) ACA 400μA/4000μA ±(1.5%+10d), 40mA/400mA ±(1.5%+10d), 10A ±(2.5%+15d) Resistance 200Ω ±(1.5%+5d) , 2000/20k/200kΩ ±(1.0%+3d) , 20MΩ ±(1.0%+5d), 200MΩ ±(1.0%(rdg-l0)+10d) Temperature -40~150˚C ±(1.0%+3d), 150-1000˚C ±(1.5%+15d)-40~302˚F(1.0%+4d), 302-1832˚F ±(1.5%+15d) Power source 1.5V AAA x 2 (not included) Accessories Test leads Square signal output 50Hz (5 Vp-p, 50KΩ)
ACV True-RMS Auto Range Pocket Size 3-3/4 digits 3999 counts DCV 400mV, 4/40/400V ±(0.5%+4d), 600V ±(1%+4d) ACV 400mV±(1.5%+6d), 4/40/400V ±(0.8%+6d), 600V ±(1.0%+6d) Resistance 400Ω ±(0.8%+5d) 4k/40k/400k/4MΩ ±(0.8%+4d), 40MΩ ±(1.2%+5d) Frequency 100/1000Hz/10k/100k/1MHz/10MHz ±(0.5%+4d) Capacitance 4nF ±(5%+40d), 40n/400n/4μ/40μ ±(3.5%+8d), 2000μF ±(5%+8d) Duty cycle 0.1~99.9% ±(0.5%+4d) Continuity with beeper 50 ±30Ω Diode test Range: 0 ~ 1.5V Resolution: 1mV Power source 2 x 1.5V AAA battery (Not included)
Amprobe DM73C Pen Probe Digital Multimeter delivers accurate 600V AC/DC readings with built-in probe, continuity beeper, and 3400-count display.
Fluke 116/62 MAX+ kit combines an HVAC multimeter with microamp and temperature testing plus a rugged IR thermometer for fast, precise HVAC diagnostics.
Compact and lightweight pocket-size device LCD display Non-contact ACV detector LED flashlight Data hold Low battery indication DCV 4200mV/2V/20V/200V±(0.5%+3d) 600V±(0.8%+5d) ACV 2V/20V/200V±(0.8%+3d) 600V±(1.0%+5d) DCA 200μA/2000μA /20mA/200mA±(1.8%+5d) ACA 200μA/2000μA /20mA/200mA±(2.0%+5d) Resistance 200Ω/2kΩ/20kΩ/200kΩ/2MΩ±(1.0%+3d) 20MΩ±(1.2%+15d) Non contact ACV detector Y Diode test Y Continuity with beep Y Certificate RoHS, CE EN61010-1 CATIII 600V Battery 2x1.5V AAA
3 1/2 digits 1999 counts Dual slope A/D conversion Large backlit LCD display
Full assortment of test functions Precise ACV ACA True RMS Measurements Overload Protection Non-contact voltage detection LCD Display 3-5/6 5999 Counts DCV 600mV/6V/60V/600V ±(0.5% +5d) ACV 600mV/6V/60V/600V ±(1% +4d) TRUE-RMS DCA 60mA/600mA ±(1.2% +5 d), 10A±(3.0% +5d) ACA 60mA/600mA ±(1.5% +5 d), 10A±(3.0% +5d)TRUE-RMS Frequency 9.999Hz/99.99Hz/999.9Hz/9.999KHz/99.99KHz/999.9KHz/9.999MHz ±(1.5% +5d) Duty Cycle 21%~99%±(2.5% +5 d) ResistanceΩ 600Ω/6k/60k/600k/6M/60MΩ ±(0.8% +5d) Capacitance 60nF/600nF/6uF/60uF/600uF/6mF ±(4% + 5d),100mF ±(4% +10d) Temperature(C/F) -20℃~1000℃±(1% + 3d) -4℉~2372℉±(1% + 3d) Continuity Buzzer ≤30Ω , buzzer beeps Diode Test Y NCV Detection Y Data Hold Y LED Light Y LCD Backlight Y Analog Bar Y Low Battery Indication Y Low Battery Indication Y Accessories Test Lead, K-type thermocouple, Manual Power 1.5V AAA x 3pcs (Not Included)
Fluke 287 multimeter: High-accuracy electronics logging with TrendCapture, real-time graphing, and Fluke Connect® compatibility for advanced diagnostics.
The Fluke 87V/E2 CAL Industrial Electrician Combo Kit centers on the Fluke 87V true-RMS digital multimeter and includes essential accessories for industrial electrical measurement. This configuration includes NIST traceable calibration with data and supports AC/DC voltage to 1000 V, AC/DC current to 10 A, resistance to 50 MΩ, capacitance to 9999 µF, frequency to 200 kHz, and temperature to 1090°C. Rated to CAT III 1000 V and CAT IV 600 V.
AEMC MTX 3292B-BT Multimeter: TRMS 100000-count with Bluetooth, USB, color LCD, IP67, and full AC/DC, temp, freq & continuity testing.
Introducing the OWON XDM1241 4 1/2 Digits Bench-Type Digital Multimeter: Precision in Every Detail.
Compact size, similar to iPhone Autoranging function True-RMS measurement Overload protection Large LCD Includes test leads Display 3 5/6 DC Voltage (V) 6V/60V/600V ±(0.8%+5d) AC Voltage (V) True-RMS 6V/60V/600V ±(1.0%+5d) DC Current (A) 1000mA/10A ±(2.0%+5d) AC Current (A) True-RMS 1000mA/10A ±(2.0%+5d) Resistance (Ω) 600Ω/6K/60K/600K/6M/60MΩ ±(1.0%+5d) Capacitance 6nF/60nF/600nF/6μF/60μF/600μF/6mF/100mF ±(4.0%+5d) Temperature -4°F~986°F ±(3%+5d) / -20°C~530°C ±(3%+5d) Frequency 1000Hz/6KHz ±(2.0%+5d) Safety CATII 600V Battery 1.5V AAA x 2
Fluke 789 ProcessMeter: Compact digital multimeter with built-in mA loop calibrator for fast, accurate troubleshooting of control loops.
The Fluke 87V MAX Digital Multimeter Solar PV Lead Kit combines the IP67-rated 87V MAX True-RMS multimeter with Pomona PVLEAD1 MC4 solar PV connector test leads. Designed for electrical troubleshooting in harsh environments, it supports AC/DC voltage up to 1000 V, 10 A current, resistance, capacitance, frequency, and temperature measurements. The included MC4 to 4 mm leads enable direct voltage verification on photovoltaic arrays while maintaining IEC / EN 61010-031 compliance.
Fluke 87V/E2 multimeter kit delivers precise True-RMS testing for industrial electricians, with VFD accuracy, peak capture, and essential accessories.
The Fluke 87V MAX E2 Kit offers a rugged true-RMS multimeter with an IP67 rating, 4 m drop protection, long battery life, and essential insulated accessories for industrial use.
Model No. MT-1210 Digits 3-1/2 digits 1999 counts Accuracy 1.0% best accuracy DCV 200mV/2V/20V/200V ±(1.0%+2d)500V ±(1.2%+5d) ACV 200/500V ±(2.5%+10d) DCA 200μ/2mA/20mA/200mA ±(2.0%+5d) 10A ±(3.0%+5d) Resistance 200Ω/2K/20K/200KΩ ±(1.0%+5d) 2MΩ ±(1.5%+5d) Extra function