Eagle Eye HGD-3000 series hydrogen gas and smoke detector monitors battery rooms and remote shelters with automatic fan control, local alarm, and relay outputs.
The Wöhler GS 300 Gas Sniffer detects combustible gas leaks with 0–1,200 ppm methane and propane sensitivity, 12-stage bar graph display, and audio, visual, and vibration alarms.
Wohler USB Peltier Cooler for A550 supports flue gas analyzer temperature control with USB-powered cooling and included battery operation for portable combustion testing workflows.
The Wöhler A 450 L Combustion Analyzer delivers flue gas analysis, burner tuning, emission measurement, and pressure testing with a 5,000 ppm CO sensor and 5" color touchscreen.
The upgrade to the Sauermann High Accuracy Draft Sensor 2 within the 500 Pascal (Pa) range signifies a noteworthy advancement in pressure measurement technology. Its incorporation of exceptional precision, an extended measurement span, and cutting-edge functionalities renders it an essential tool.
The Sauermann SICA 2306NDSH gas analyzer supports Oâ‚‚, CO, NO, NOâ‚‚, SOâ‚‚, and Hâ‚‚S measurement with CO dilution auto-range to 50K ppm for combustion and emissions analysis workflows.
The Sauermann SICA 2305NDS combustion gas analyzer brings five-gas measurement capability to flue gas analysis, emissions checks, pressure testing, ambient CO/CO2 monitoring, and combustion diagnostics.
Eagle Eye GD-3000 combustible gas detector with selectable methane, propane, or hydrogen detection, digital display, alarm buzzer, fan relay, alarm relay, and 4-20 mA output.
The Sauermann SICA 2302 Si-CA 230 delivers combustion gas analysis with O2 and CO sensing, data logging, report creation, pump purge control, wireless/USB PC connectivity, and high-CO protection.
The Sauermann 10-foot Hose Extension, featuring a dual hose design and temperature resistance, is a dependable accessory that improves the performance of air conditioning and refrigeration systems due to its optimal blend of length and functionality.
Sauermann SiCA 230-5NSH combustion gas analysis delivers measurement of O2, CO, NO, SO2, and H2S with advanced data logging, reporting, emissions calculations, and connectivity for residential, commercial, and industrial combustion applications.
The Sauermann SICA 2303NL Combustion Gas Analyzer delivers O2, CO, and Low NO measurement with advanced combustion diagnostics, wireless connectivity, automatic data logging, emissions calculations, and predictive maintenance tools for residential, commercial, and industrial combustion analysis.
Eagle Eye Power Solutions VS-Series ventilation system provides 1050 CFM forced-air exhaust for battery rooms, helping purge hydrogen and other gases.
The Sauermann Low NO2 Sensor (0-100ppm) equipped with a Si-CA 230 Upgrade board is an indispensable instrument for individuals in need of accurate and dependable monitoring of NO2 gas across a broad range of concentrations.
Sauermann Si-CA 230 SICA 2305NLDLSL gas analyzer delivers combustion gas analysis with O2, CO, Low NO, Low NO2, and Low SO2 measurement capability for residential, commercial, and industrial workflows.
The Sauermann NO Sensor (0-5000ppm) with a dedicated board designed for upgrading Si-CA 130/230 offers an advanced solution for the precise monitoring and control of Nitric Oxide gas levels. Its accuracy, compatibility, and effortless integration make it a sophisticated choice.
Pitot Tube Specifications
Wöhler A 450 Combustion Analyzer delivers residential flue gas analysis, burner tuning, emission measurement, O₂ measurement, 10,000 ppm CO measurement, and differential pressure testing from a 5" color touchscreen platform.
WOHLER A450 10,000 PPM CO Sensor Set: Your Complete Combustion Analyzer Solution
Eagle Eye HGD-4000 hydrogen gas detector with intrinsically safe design, AC power input (85–265 VAC), dual internal alarm relays, and LED status indication.
Sauermann SICA 2304ND Si-CA 230 delivers four-gas combustion analysis for O2, CO, NO, and NO2 with logging, reporting, purge control, and high-CO protection.
Sauermann Si-CA 030 KIT 3AS delivers compact combustion gas analysis for residential and commercial boiler service with O2, CO, and NO measurement, wireless reporting, draft measurement, and combustion calculations.
Sauermann SICA 2304NC combustion gas analyzer brings sharp 4-gas flue gas analysis with O2, CO, NO, and CxHy measurement, plus logging, reporting, draft, pressure, ambient CO/CO2 monitoring, and PC connectivity.
WOHLER A450 10,000 PPM CO Sensor: Unleash Precision and Versatility
The Wöhler A 450 L Combustion Analyzer Advanced Set delivers residential combustion analysis, burner tuning support, emission measurement, pressure testing, Wi-Fi workflow, and on-site printing.