The Fujikura 70S is the fast and robust core alignment fusion splicer, with rubberized housing protection, providing stable and high–quality welding of optical fibers with low insertion losses. A user programmable, automated wind protector expedites the splicing process by automatically closing to initiate the splice process, and opening upon splice completion.
Wohler 17535 delivers bold chimney and flue cleaning reach with a 35 cm hard flatwire spring steel brush and M10 threaded connection for professional soot and deposit removal.
The Siemens 75D73070C AC coil set of 2 offers clearly labeled 50/60 Hz voltage ranges and V/W terminal markings for starter and contactor replacement needs.
INNO Instrument PAC-1007 small alligator adapter pair with safety connector, rated 300V CAT II 15A, in red and black.
Fisher SONDE-82.175 is an 82.175 kHz sonde for TW9000 line tracers. This self-contained transmitter helps locate non-metallic pipes, ducts, and blockages for fast, accurate underground tracing.
Fisher SONDE-82.175 is an 82.175 kHz self-contained transmitter for locating underground utilities. Compatible with TW82 and TW8800 line tracers, it helps trace non-metallic pipes and ducts accurately.
The Inno Instrument HDMI to USB Cable is a communication interface designed for Inno Instrument VIEW series fusion splicers, including VIEW 3, VIEW 5, VIEW 7, and VIEW 12R models. It connects the splicer’s Micro HDMI port to a standard USB Type-A port on a computer for data transfer, software updates, and graphical interface mirroring.
The Fluke I17XX-FLEX3000/4PK includes four 24 in iFlex® flexible AC current probes rated to 3000 A AC. Designed for use with Fluke 17XX Energy and Power Loggers, these Rogowski-style probes connect directly to the instrument and feature 1.8 m output cables for measurement flexibility.
Fluke 62 MAX CAL infrared thermometer delivers non-contact temperature measurement with a 10:1 distance-to-spot ratio, IP54 protection, single-laser targeting, and traceable calibration data for dependable industrial diagnostics.
The MEAN WELL HRP-600-15 is a single-output enclosed AC-DC power supply delivering 15 VDC at up to 43 A. It features built-in active power factor correction, fan cooling with ON-OFF control, and protection against overload, over-voltage, and over-temperature for industrial power applications.
Fluke 1535 Insulation Resistance Tester delivers 250V–2500V testing with insulation measurements up to 500 GΩ. Designed for industrial and solar environments with CAT IV 600V safety and automatic PI/DAR calculations.
Fluke 190-204-III is a 4-channel portable ScopeMeter oscilloscope with 200 MHz bandwidth, isolated inputs, WiFi and USB connectivity, built for high-voltage industrial signal troubleshooting.
Fluke FLK-FEV150/TY1 EV Charging Station Analyzer enables fast, safe AC EVSE testing with Type 1 connector, auto control pilot simulation, and guided workflows.
Allen-Bradley 871C-C5A18 inductive proximity sensor delivers reliable non-contact metal detection with a 5 mm sensing range, normally closed output, and AC 2-wire operation for industrial automation applications.
Fluke CFP-SM MOD module delivers fast singlemode OLTS certification with Taptive interface, accurate referencing, and seamless Versiv platform integration.
United Conveyor Supply Co 34592-1 NEMA 4 Junction Box offers durable, weatherproof protection for industrial wiring and controls in harsh indoor or outdoor environments.
Fluke A3001 FC: Wireless iFlex AC current module delivers true-RMS measurements, backlight display, and safe remote monitoring via Fluke Connect app.
Fluke RS-1007 PRO Analog Clamp Meter: CAT IV 600V rated, measures AC current, voltage, resistance, and continuity without battery for main functions.
Fluke 323 clamp meter for accurate AC/DC voltage and current testing up to 600V/400A with True RMS, slim design, and data hold for easy diagnostics.
AEMC 2620 Leakage Current Probe: Detect low-level ground and differential faults with high accuracy, large jaw opening, and DMM compatibility.
Autel Robotics delivers high-performance drone technology with the Alpha L35T Gimbal. Capture stunning 4K video and precise thermal imaging with ease.
EPOCH 4 Ultrasonic Flaw Detector: High-res display, customizable filters, and 7-hour battery life for precise, reliable inspections in various industries. Built for performance.
The Megger Sverker 750 Relay Test Set is the ultimate toolbox for engineers, featuring a logical control panel layout that is familiar to SVERKER 650 users, ensuring immediate usability. It offers a powerful measurement section capable of displaying time, voltage, current, Z, R, X, S, P, Q, phase angle, and cos, enhancing relay testing efficiency. The voltmeter doubles as a secondary ammeter for differential relay testing. With its clear and easy-to-read display, all measurements are conveniently presented. The Sverker 750 incorporates a versatile built-in current source, providing outputs ranging from 0-10A to 0-250V AC or 0-300V DC. Designed to comply with EU and safety standards, it includes a serial port for seamless communication with personal computers using the SVERKER Win software. In addition to its extensive range of single-phase relay testing applications, covering relays such as overcurrent, undercurrent, ground fault, directional overcurrent, overvoltage, undervoltage, and more, the Sverker 750 boasts a variety of extra features. These include excitation curve plotting, transformer ratio tests, burden measurement, impedance measurement, efficiency tests, polarity tests, injection with various modes, filtering for averaged readings, and off delay functionality for delayed generation shutdown after tripping.