JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
Try searching for keywords in categories, brands, products, and more. If you have any questions, please contact our Support team
Out of stock
Shopping cart
Your cart is empty
Looks like you haven't made your choice yet.
x
SKU:
Subtotal:
Total:
My Quote
Your Quote is empty
Checkout using your account
This form is protected by reCAPTCHA - the Google Privacy Policy and Terms of Service apply.
Checkout as a new customer
Creating an account has many benefits:
Fluke Networks P4480004 replacement line cord designed for TS52, TS44, and TS42 test sets. Features a durable braided cable and integrated 346A plug for reliable field testing instrument connectivity.
Wöhler 8713 delivers wide 13x13 in Perlon push-head brushing for ventilation line cleaning, with a 3-layer brush layout and M10 thread connection.
The PLS 180R RBP KIT Cross Line Red Laser Level Kit provides a self-leveling cross line laser with ≤1/8 in accuracy at 30 ft (≤3 mm @ 10 m). It features a 180° horizontal fan angle, 130° vertical fan angle, pendulum lock for transport protection, IP54 rating, and includes rechargeable and alkaline battery packs with mounting accessories.
Certified pre-owned Sonatest RDT2520, 20 MHz 1/4" delay line compression wave ultrasonic transducer—engineered for high-resolution flaw detection and ultra-thin material inspection. Compatible with Sonatest Sitescan, Prisma, Veo+, and Masterscan flaw detectors.
Fluke Networks 10300000 modular 8-wire cords provide reliable test access for telecom lines, available in standard or rugged K-plug versions. Pack of five.
Allen-Bradley 2706-B21J16 DL20 two-line message display provides clear ASCII text output from a host controller using RS-232, RS-422, or parallel communication for industrial notification systems.
Allen-Bradley 1334-50907 Line/Converter Power Module for Bulletin 1334 AC drives. Internal power board supporting sine-weighted PWM motor control in 5–10 HP variable frequency drive systems.
Wöhler 8711 Perlon Push-Head Brush delivers 8 x 8 in M10-thread cleaning coverage with a 3-layer Perlon head for ventilation-line cleaning workflows.
Swagelok SS-4BHT-12 is a T Series PTFE-lined stainless steel braided hose assembly with dual 1/4 in. Swagelok tube adapters. It features a 14 in. hose length with 10.2 in. live length and a temperature range of -65°F to 450°F.
Fisher TW82P Digital Line Tracer 82.175 kHz utility locator for buried pipe and cable tracing. Features Passive Power Mode, automatic depth and current measurement, and conductive or inductive signal application.
Fisher CASE-TW82 soft carrying case fits TW-82 and TW-82P line tracers. Lightweight vinyl design protects from dust and minor impacts while keeping transmitter, receiver, and accessories organized.
Allen-Bradley 700-HK36Z24 relay delivers reliable 24V DC SPDT control switching for automation panels, compatible with 700-HN121 slim-line sockets.
Fluke Networks P3218028 line cord with angled piercing pin clips enables testing of insulated telephone wires with compatible TS series test sets.
Wohler VIS Camera Trolley Set 4753 keeps inspection camera heads centered and controlled in drain pipes, air lines, and drawn chimneys with adjustable positioning and smooth rolling guidance.
Fluke Networks P4480RJ9 replacement line cord features RJ11 to angled bed-of-nails clips, delivering clear voice quality for TS52, TS44, and TS42 test sets.
Allen-Bradley 1336-SCR-SP3A Input SCR Power Module for 1336 Adjustable Drives. Designed for 460V AC line-side rectification in Frame D drives supporting 60–100 HP systems.
Fisher CASE-TW82HC hard case for TW-82 and TW-82P line tracers. Impact-resistant shell with custom foam protects transmitter, receiver, and accessories during transport and field use.
Allen-Bradley 813S-V0WE line voltage monitor relay designed for three-phase systems to detect phase loss, phase reversal, and voltage unbalance, providing automatic protective signaling in motor control circuits.
Fluke Networks TS19 Test Set: Reliable in-house telecom testing with talk/monitor, polarity check, DTMF/pulse tone, and last-number redial.
Wöhler VIS 250 Inspection Camera delivers clear visual inspection for 1.5 in. and larger waste water pipes and ventilation lines, hollow spaces, and flue gas lines up to approx. 6 in., with a bright 7 in. display and electronic distance counter for fast diagnostics.
The Fluke Networks TS52 PRO (52801001) is a telephone-test set that combines a back-lit LCD, glow-in-the-dark keypad and DataSafe Pro high-impedance monitoring with piercing-pin clip connectors—ideal for rugged outside-plant voice/data line work.
AEMC ALS-1 AC Line Splitter: Boost clamp meter sensitivity with X1 and X10 clamp positions plus voltage checking for safe, accurate current measurement.
Fluke Networks P3080001 line cord features piercing pin clips for testing insulated telephone wires with TS30 and TS120 test sets.
Leica Piper 100 3R red beam pipe laser with IRPL200 remote, target assembly with reflective inserts, and 150 mm self-centering feet for accurate line and grade alignment in sewer and utility pipelines.
The General Electric CR305X100E is a side-mounted auxiliary contact adder block providing one normally closed (1 NC) contact for GE 200- and 300-Line starters and contactors. It is designed for field installation onto a basic auxiliary contact block and is rated up to 600 VAC and 250 VDC.