JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
Try searching for keywords in categories, brands, products, and more. If you have any questions, please contact our Support team
Out of stock
Shopping cart
Your cart is empty
Looks like you haven't made your choice yet.
x
SKU:
Subtotal:
Total:
My Quote
Your Quote is empty
Checkout using your account
This form is protected by reCAPTCHA - the Google Privacy Policy and Terms of Service apply.
Checkout as a new customer
Creating an account has many benefits:
Phoenix Contact PLC-BSC-24UC/21-21 relay base for 24V AC/DC PLC relays, with LED status display and DIN rail mounting, ideal for automation control systems.
Allen-Bradley 1794-TB32S offers reliable spring-clamp wiring for Flex I/O 32-point modules, delivering quick installation, RIUP support, and secure DIN-rail mounting.
Bürkert Type 6011 00271765 solenoid valve delivers reliable direct-acting flow control for industrial systems, compatible w/ 24 V AC setups and Bürkert cable plugs.
Single Fluke DTX-MFM2 multimode fiber module for 850/1300 nm dual-fiber loss and length testing. Supports SC output, interchangeable adapters, VFL, and FindFiber functions.
The Fluke Biomedical ESA615 Electrical Safety Analyzer is an all-in-one portable instrument combining a full electrical safety tester and ECG simulator, designed for healthcare technology management professionals. It automates compliance testing to ANSI/AAMI ES1, NFPA-99, IEC62353, IEC60601-1 (2nd/3rd Editions), and AS/NZS 3551 standards.
Olympus AM4R-20X22-60 is a 4 MHz, 20x22 mm angle beam shear wave ultrasonic probe (Atlas Series) with a 60° angle in steel and right angle LEMO 1 connector. Designed for high-resolution weld inspection and flaw detection in demanding NDT applications.
Olympus AM4R-20X22-45 is a 4 MHz, 20x22 mm angle beam shear wave ultrasonic probe (Atlas Series) with a 45° angle in steel and right angle LEMO 1 connector—high-resolution weld inspection and flaw detection capability.
Olympus AM2R-20X22-70 is a 2 MHz, 20x22 mm angle beam shear wave ultrasonic probe (Atlas Series) with a 70° angle in steel and right angle LEMO 1 connector—ideal for weld and flaw inspection in heavy industry.
Olympus AM2R-20X22-60 is a 2 MHz, 20x22 mm angle beam shear wave ultrasonic probe (Atlas Series) with a 60° angle in steel and right angle LEMO 1 connector—ideal for weld inspection and flaw detection.
Olympus AM1R-20X22-70 is a 1 MHz, 20x22 mm angle beam shear wave ultrasonic probe (Atlas Series) with a 70° angle in steel and right angle LEMO 1 connector—ideal for deep-penetration weld inspection and flaw detection.
Used Sonatest CDA2525270T, 2.5 MHz 1" twin element compression wave ultrasonic transducer with top exit for reliable thickness surveys and flaw detection in steel, pipelines, and tanks. Compatible with Sonatest Wave, Sitescan D-50, and Masterscan D-70. Order from Cartoli or call 1-833-322-7865.
Used Sonatest PIM5025, 2.25 MHz, 0.5" immersion ultrasonic transducer for flaw detection andprecision NDT in composites, metals, and ceramics. Compatible with Sonatest Wave, Sitescan D-50, Masterscan D-70, and Prisma. Order from Cartoli or call 1-833-322-7865.
Used Sonatest L15K12A, 15 MHz, 12 mm single element compression probe for high-resolution flaw detection and thickness gauging in thin materials. Compatible with Sonatest Wave, Masterscan 700M, Sitescan D-50. Request a quote or contact us today.
Used Sonatest PSLF5050, 2.25 MHz, 1" soft face, medium damped ultrasonic contact transducer for flaw detection in castings and rough surfaces. Use with couplants, wedges, or flaw detectors. Contact us or request a quote for reliable used NDT equipment.
The Tempo 180XL visual fault locator offers a fast and safe method for technicians to visually identify fiber optic faults like breaks, pinches, bad connectors, and poor splices. It also allows for safe confirmation of fiber continuity thanks to its long reach.
Manufacturer Refurbished Thermo Scientific Niton XL3t 700S XRF Analyzer: Precision testing for metals, gold, silver, plastics & consumer goods with advanced Spectral Fingerprint technology.
Complete Pruftechnik ROTALIGN Ultra kit with Shaft Alignment Advanced license, ROTALIGN sensor and laser, Bluetooth module, chain and magnetic bracket sets, cables, software, and ABS transport case.
Portable, durable, and easy to use Supports 2.5mm universal connectors (for FC/SC/ST) Dust-proof & crash-proof cap design for laser head Wavelength 650 nm±10 nm Output Power 1 mW Laser CLASS II Tested fiber length 3-5 km Power (batteries) AA (1.5 V) x 2 Connector 2.5mm universal connector for FC, ST and SC OAL 7 in. Operating Temperature -10~55°C Storage Temperature -10~70°C Optional Accessory LC 1.25mm adaptor(5MT-7601-LC)
Product Overview
Olympus IV0620 Series C Videoscope: Compact, durable, and ergonomic inspection tool. 120 min battery life, HDMI output, ideal for hard-to-reach industrial inspections.
Certified pre-owned Rohde & Schwarz ZVH4 3.6 GHz Cable & Antenna Analyzer with Rosenberger RPC-N 92A79 precision connector, RF cable assemblies, Huber + Suhner 18A test cable, charger, and accessories. Designed for antenna installation and maintenance with DTF, VSWR, and cable loss functions. Function-tested and ready for the field.
Siemens 3RH1131-1AK60 contactor relay delivers 3NO+1NC switching in a compact SIRIUS S00 format with a 110V 50 Hz / 120V 60 Hz AC coil and screw-terminal connection for control circuit integration.
Moore Industries TIY/PRG/4-20MA/12-42DC [DIN] is a programmable isolated thermocouple transmitter that accepts common thermocouple types and millivolt inputs and delivers a linear 4-20mA output with front-panel ranging, display indication, and self-diagnostics.
INNO Instrument M7+ compact fusion splicer kit with Active V-Groove cladding alignment and a 4.3" full-touch display. Supports single-fiber SM/MM/DS/NZDS splicing, quick splice/heating cycles, and data output via USB-C or View Pro Manager cloud.
The Fluke 810 Vibration Tester is a handheld diagnostic instrument for identifying mechanical vibration faults in rotating equipment. Using tri-axial measurement and on-device analysis, it reports fault type, location, and severity during field testing.