Emerson Ovation 1C31219G01 Relay Output Electronics Module for interfacing between the Ovation controller and mechanical relays in a relay output assembly.
AutomationDirect D2-08NA-1 is an 8-point AC input module for DL205 PLC systems with 80-132 VAC input range, 47-63 Hz operation, removable terminal connection, and logic-side status indication.
INNO Instrument PTB01 is a single-phase wiring test adapter box used for switching single-phase circuits to support power coefficient measurement and related electrical testing workflows.
The INNO Instrument ACC-25-B Power Cable provides AC input connection for INNO Instrument devices that use the JS-180300 AC charging adapter. The cable connects the adapter block to a standard AC wall outlet and is used with compatible INNO Instrument OTDRs and fusion splicers.
Fisher 203-168-00-00 Multi-Sensor microphone for XLT30. Versatile acoustic sensor for underground leak detection on concrete, asphalt, tile, and turf, with surface listening and pipe contact capability.
Fisher XLT30-B acoustic leak detector with Multi-Sensor provides precise water leak detection using adjustable filters, notch rejection, and high-sensitivity microphones for concrete, asphalt, and turf surfaces.
The INNO Instrument JS-1500 is a 12V DC AC power adapter and charger designed for INNO thermal strippers including the TS-PRO and TS-PLUS. It provides stable DC output for heater operation while recharging the internal battery.
Fisher TW82 Digital Line Tracer delivers 82.175 kHz utility locating with Normal and Lateral modes for tracing buried pipes and cables using conductive or inductive methods.
The INNO Instrument JS-180300 is a 19V AC adapter and battery charger designed for INNO View series fusion splicers and compatible instruments. It provides 19V DC output at 3.42A with universal 100–240V AC input, supporting global mains standards. Desktop-style construction with attached DC output cable.
The Siemens 771-8STF2 is a Series 771 current-to-pneumatic transducer that converts a 4–20 mA DC input signal to a 3–27 psig pneumatic output. This standard-capacity unit provides 0.16 scfm output and is configured with terminal strip connection and F2 non-incendive hazardous location approval.
The Allen-Bradley 1606-XLE480EP is a 24V DC, 20A (480W) switched mode power supply from the 1606-XLE Essential series. It supports 100–240V AC input and 110–150V DC input, features adjustable 24–28V output, 20% power reserve, DC OK relay contact, and screw terminals for DIN rail industrial installation.
The Ferraz Shawmut USCC3 (M217522) is a 3-pole Class CC fuse holder rated 30A and 600 VAC/VDC. Designed for 35mm DIN rail mounting, it features IP20 finger-safe protection, pressure plate terminals, and a 200 kA SCCR for industrial circuit protection applications.
The Contrex M-Drive 4E is a digital DC motor drive and motion controller designed for closed-loop speed regulation of permanent magnet DC motors up to 2 HP. It supports dual AC input voltage, selectable DC output, serial communication, and integrated operator interface.
The TCI AS-B875-002 KLC25BE dv/dT Guard Output Filter is designed to protect AC motors driven by PWM variable frequency drives. Rated for 25 A, 3-phase, 480 V systems, it limits voltage spikes and dV/dt effects that can damage motor insulation and cabling.
Fluke FLK2AC/90-1000V5PK VoltAlert non-contact voltage detector 5-pack senses 90–1000V AC through insulation, featuring always-on operation, battery check, and CAT IV 1000V safety rating.
Moore Industries DPS 240 DIN-style power supply configured for 42 VDC output at 240 mA from a 117 VAC input. Linear regulated design with adjustable voltage, current limiting, and isolated output for powering 2-wire transmitters and instrumentation circuits.
Fluke 718Ex 30 intrinsically safe pressure calibrator delivers accurate 30 PSI gauge pressure testing with a built-in hand pump, current measurement, and ATEX-rated safety for hazardous-area calibration work.
Fluke V3000 FC Wireless AC voltage module measures up to 1000 V true-RMS and logs data wirelessly using Fluke Connect for real-time sharing.
Fluke LVD2 CT Volt Light detects 90–600 V AC without contact, using dual-sensitivity LED indicators and an ultra-bright flashlight for safe voltage checks.
Fluke 717 15G Pressure Calibrator delivers precise -12 to 15 psi measurements with 0.05% accuracy, mA measurement, and compact field-ready design.
General Electric 36A352951 AC-A circuit board with tag 356X479TAG01, designed for industrial control systems requiring analog AC signal processing within GE automation and power control platforms.
Allen-Bradley 800T-FXJE6A5 emergency stop pushbutton with maintained push-pull action, jumbo red E-STOP mushroom head, and dual normally closed late-break contacts for industrial safety circuits.
Allen-Bradley 1772-SD2 remote I/O scanner enables PLC-2 processors to communicate with remote I/O racks, supporting up to 1792 I/O points with serial twinaxial connectivity and LED status indicators.
Allen-Bradley S50411-002 dynamic brake board enables controlled motor deceleration by managing regenerative energy through external brake resistors in compatible 1305 variable frequency drives.
Allen-Bradley 1334-MOD-W3 run/fault contact mod kit adds isolated relay outputs for remote drive status monitoring on Bulletin 1334 and 1335 AC drives, supporting external control and annunciation systems.