Replacement hex die for 12 Ton Hydraulic Crimpers (902-480 / 902-600).
Fluke BK120-T5-600 kit combines a smart circuit breaker finder with a T5-600 tester for fast breaker identification and safe voltage, current, and continuity checks.
Fluke T5-600 tester offers fast AC/DC voltage, continuity, and 100 A current checks with OpenJawâ„¢ design and detachable SlimReachâ„¢ probes.
Amprobe AMP-220 Clamp Meter delivers accurate 600A AC/DC measurements with True-RMS, Amp-Tip, backlit display, and non-contact voltage detection.
Bussmann LPJ-5SP Low-Peak time-delay fuse provides dual-element, current-limiting circuit protection for 600VAC-or-less applications.
The Fluke T5-600/62 MAX+/1AC II kit combines voltage, current, and continuity testing with infrared temperature measurement and non-contact voltage detection. The kit includes the T5-600 electrical tester, 62 MAX+ IR thermometer, and 1AC II VoltAlert tester for electrical troubleshooting and inspection tasks.
The MEAN WELL HRP-600-15 is a single-output enclosed AC-DC power supply delivering 15 VDC at up to 43 A. It features built-in active power factor correction, fan cooling with ON-OFF control, and protection against overload, over-voltage, and over-temperature for industrial power applications.
AEMC 2970.97 Fuse Set delivers reliable 0.5A, 600V HPC protection with 6x32mm size, designed specifically for Model 6527 equipment.
Fluke AC89 Test Clip: Insulation piercing probe with CAT IV 600V safety, 5A rating, and UL listing for reliable wire testing and diagnostics.
Full assortment of test functions Precise ACV ACA True RMS Measurements Overload Protection Non-contact voltage detection LCD Display 3-5/6 5999 Counts DCV 600mV/6V/60V/600V ±(0.5% +5d) ACV 600mV/6V/60V/600V ±(1% +4d) TRUE-RMS DCA 60mA/600mA ±(1.2% +5 d), 10A±(3.0% +5d) ACA 60mA/600mA ±(1.5% +5 d), 10A±(3.0% +5d)TRUE-RMS Frequency 9.999Hz/99.99Hz/999.9Hz/9.999KHz/99.99KHz/999.9KHz/9.999MHz ±(1.5% +5d) Duty Cycle 21%~99%±(2.5% +5 d) ResistanceΩ 600Ω/6k/60k/600k/6M/60MΩ ±(0.8% +5d) Capacitance 60nF/600nF/6uF/60uF/600uF/6mF ±(4% + 5d),100mF ±(4% +10d) Temperature(C/F) -20℃~1000℃±(1% + 3d) -4℉~2372℉±(1% + 3d) Continuity Buzzer ≤30Ω , buzzer beeps Diode Test Y NCV Detection Y Data Hold Y LED Light Y LCD Backlight Y Analog Bar Y Low Battery Indication Y Low Battery Indication Y Accessories Test Lead, K-type thermocouple, Manual Power 1.5V AAA x 3pcs (Not Included)
Fluke T5-RLS test leads: reliable replacements for T5-600 and T5-1000 testers, delivering accurate connections and lasting durability.
3 5/6 digits 5999 counts 0.5% best accuracy Dual display with analog bargraph Auto/Manual ranging USB data upload Measurement Range DC Voltage (DCV) 600m/6/60/600V ±(0.5%+4d), 1000V ±(1.0%+6d) AC Voltage (ACV) 6/60/600V ±(0.8%+10d), 750V ±(1.0%+10d) DC Current (DCA) 600μ/6000μA ±(1.0%+10d), 60m/600mA ±(1.0%+10d), 6/10A ±(1.2%+10d) AC Current (ACA) 600μ/6000μA ±(1.5%+10d), 60m/600mA ±(1.5%+10d), 6/10A ±(2.0%+15d) Resistance 600Ω ±(0.8%+5d), 6k/60k/600k/6MΩ ±(0.8%+4d), 60MΩ ±(1.2%+10d) Frequency 100/1000Hz ±(0.5%+4d), 10k/100kHz ±(0.5%+4d), 1M/30MHz ±(0.5%+4d) Capacitance 40nF±(5%+30d), 400n/4μ/40μF±(3.5%+8d) 200μF±(5.0%+10d) Temperature -20~400˚C(0~750˚F) ±(1.0%+5d), 400~1000˚C(750~1832˚F) ±(1.5%+15d) Continuity with Buzzer Yes Diode Test Yes Transistor Test Yes Power Source AAA(1.5V)×2pcs (Not included)
Genteq 97F8245S 5 µF 600 VAC run capacitor delivers reliable AC motor performance with long-life polypropylene film and PSI protection for general power applications.
The Schrack ZG400615 is a used ice cube relay rated for 5 Amps and up to 600 Volts. It features a 14-pin plug-in design and a 115 VAC coil voltage, making it suitable for general industrial control and electrical switching applications where reliable electromechanical control is required.
AEMC MD305 AC current probe: 600A range with 1mA/A output, rugged clamp design, banana plugs, ideal for meters with ≤5Ω input.
EXFO FLS-600 Light Source: Versatile, reliable, and durable. Ideal for testing fiber optics with up to 50 hours of battery life. Accurate, portable, and easy to use.
Amprobe DM73C Pen Probe Digital Multimeter delivers accurate 600V AC/DC readings with built-in probe, continuity beeper, and 3400-count display.
Olympus EPOCH 600 Ultrasonic Flaw Detector: Reliable, high-precision testing for industrial applications. Compact design, long battery life, and advanced AWS & API5UE options.
Compact size, similar to iPhone Autoranging function True-RMS measurement Overload protection Large LCD Includes test leads Display 3 5/6 DC Voltage (V) 6V/60V/600V ±(0.8%+5d) AC Voltage (V) True-RMS 6V/60V/600V ±(1.0%+5d) DC Current (A) 1000mA/10A ±(2.0%+5d) AC Current (A) True-RMS 1000mA/10A ±(2.0%+5d) Resistance (Ω) 600Ω/6K/60K/600K/6M/60MΩ ±(1.0%+5d) Capacitance 6nF/60nF/600nF/6μF/60μF/600μF/6mF/100mF ±(4.0%+5d) Temperature -4°F~986°F ±(3%+5d) / -20°C~530°C ±(3%+5d) Frequency 1000Hz/6KHz ±(2.0%+5d) Safety CATII 600V Battery 1.5V AAA x 2
Fluke LVD2 detects AC voltage from 90 to 600 V with dual sensitivity and LED flashlight. Safe CAT IV 600 V rating for industrial and commercial use.
The Fluke i1010 is an AC/DC current clamp designed for use with digital multimeters. It measures currents from 1 A up to 1000 A DC and up to 600 A AC using a Hall-effect sensor. The clamp outputs 1 mV per amp for direct reading on compatible meters.
Fluke RS-1007 PRO Analog Clamp Meter: CAT IV 600V rated, measures AC current, voltage, resistance, and continuity without battery for main functions.
AEMC 5000.50 Probe 10:1 BNC Male for OX5022 & OX5042 kits. Durable 600V input for precise test measurements. Compact, reliable, and easy to connect.
AEMC MR417 Probe: Dual range AC/DC hall effect probe for oscilloscopes, 40A/400A & 60A/600A, BNC output, USB/battery power, auto zero adjust.
AEMC MR415 Current Probe: AC/DC hall effect probe with 400AAC/600ADC range, 1mV/A output, 4mm banana plugs, auto zero, USB/battery power.