JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
Try searching for keywords in categories, brands, products, and more. If you have any questions, please contact our Support team
Out of stock
Shopping cart
Your cart is empty
Looks like you haven't made your choice yet.
x
SKU:
Subtotal:
Total:
My Quote
Your Quote is empty
Checkout using your account
This form is protected by reCAPTCHA - the Google Privacy Policy and Terms of Service apply.
Checkout as a new customer
Creating an account has many benefits:
Fluke flexible current probe delivers accurate 6000A AC measurement for 430 Series II power quality tools, ideal for advanced electrical testing.
Fluke 115: Compact True RMS digital multimeter with 600V/10A capacity, backlight display, and CAT III 600V safety for versatile field service use.
AEMC 5000.50 Probe 10:1 BNC Male for OX5022 & OX5042 kits. Durable 600V input for precise test measurements. Compact, reliable, and easy to connect.
Compact size, similar to iPhone Autoranging function True-RMS measurement Overload protection Large LCD Includes test leads Display 3 5/6 DC Voltage (V) 6V/60V/600V ±(0.8%+5d) AC Voltage (V) True-RMS 6V/60V/600V ±(1.0%+5d) DC Current (A) 1000mA/10A ±(2.0%+5d) AC Current (A) True-RMS 1000mA/10A ±(2.0%+5d) Resistance (Ω) 600Ω/6K/60K/600K/6M/60MΩ ±(1.0%+5d) Capacitance 6nF/60nF/600nF/6μF/60μF/600μF/6mF/100mF ±(4.0%+5d) Temperature -4°F~986°F ±(3%+5d) / -20°C~530°C ±(3%+5d) Frequency 1000Hz/6KHz ±(2.0%+5d) Safety CATII 600V Battery 1.5V AAA x 2
Model No. MT-1210 Digits 3-1/2 digits 1999 counts Accuracy 1.0% best accuracy DCV 200mV/2V/20V/200V ±(1.0%+2d)500V ±(1.2%+5d) ACV 200/500V ±(2.5%+10d) DCA 200μ/2mA/20mA/200mA ±(2.0%+5d) 10A ±(3.0%+5d) Resistance 200Ω/2K/20K/200KΩ ±(1.0%+5d) 2MΩ ±(1.5%+5d) Extra function
Amprobe PM55A Pocket Multimeter offers AutoTect automatic AC/DC detection, non-contact voltage sensing, and versatile measurement functions in a compact design.
Fluke 88-5 automotive meter delivers precise voltage, current, and pulse width diagnostics for modern and hybrid vehicles with advanced recording features.
AEMC E94 AC/DC Current Probe: Compact, Hall-effect design with 100A range, zero DC reset, and auto recognition for PowerPad 8345 & PEL loggers.
AEMC 5100.11 Universal Spline Adapter: Reliable replacement for Model 275HVD, fits in place of discontinued 5100.08 spline adapter.
Use the Fluke VPS410-II-B (Blue) Voltage Probe with the Fluke 190 Series III and Series II Portable Oscilloscopes or with the MDA-500 Series Motor Drive Analyzers. These double insulated probes offer a 10:1 voltage ratio, and 500 MHz bandwidth making them ideal for industrial, electrical and electronics testing. Key features Ideal for industrial and electronics applications Double insulated, CAT III 1000V / CAT IV 600V rated 10:1 voltage ratio and 500 MHz bandwidth
Megger MIT1025 Insulation Tester: Measure insulation resistance up to 10kV with advanced diagnostics. Fast, reliable, and built for high-performance testing.
Megger PAT420 Electrical Tester: Reliable, high-performance testing for earth bond, insulation, and more. Perfect for safety with easy-to-read LCD display. Made for professionals.
AEMC 6472 Digital tester measures ground, bond resistance, soil resistivity, step & touch potential with DataView software for easy analysis.
AEMC MN05 AC current probe with dual ranges 10A & 100A, voltage outputs 1mV/A & 1mV/mA, compact design with 5 ft lead for tight spaces and low current use.
Amprobe LH41A clamp-on ammeter delivers precise low-current measurement with 1 mA resolution, data hold, and CAT III 300 V safety.
Fluke 393 CAT III 1500V clamp meter delivers true RMS AC/DC measurements up to 2500A with iFlex probe and IP54 protection for harsh environments.
Fluke VoltAlert 2AC/90-1000VC detects 90–1000V AC without contact, LED indicator, pocket-sized, battery-powered, ideal for electricians and home use.
Amprobe DM73C Pen Probe Digital Multimeter delivers accurate 600V AC/DC readings with built-in probe, continuity beeper, and 3400-count display.
Fluke T6-600: Measure AC voltage and current without test leads using FieldSenseâ„¢. True RMS accuracy, backlit display, and compact design.
Megger DLRO 10X: High-precision digital ohmmeter for low resistance testing. Ideal for industrial use, offering 700 test capacity and reliable, fast performance.
Certified pre-owned Megger MIT1025: 10 kV insulation resistance tester designed for high-voltage equipment diagnostics. It delivers fast, stable readings up to 20 TΩ, supports PI/DAR testing, and includes advanced filtering for noisy environments—ideal for substations, motors, cables, and transformers.
Full assortment of test functions Precise ACV ACA True RMS Measurements Overload Protection Non-contact voltage detection LCD Display 3-5/6 5999 Counts DCV 600mV/6V/60V/600V ±(0.5% +5d) ACV 600mV/6V/60V/600V ±(1% +4d) TRUE-RMS DCA 60mA/600mA ±(1.2% +5 d), 10A±(3.0% +5d) ACA 60mA/600mA ±(1.5% +5 d), 10A±(3.0% +5d)TRUE-RMS Frequency 9.999Hz/99.99Hz/999.9Hz/9.999KHz/99.99KHz/999.9KHz/9.999MHz ±(1.5% +5d) Duty Cycle 21%~99%±(2.5% +5 d) ResistanceΩ 600Ω/6k/60k/600k/6M/60MΩ ±(0.8% +5d) Capacitance 60nF/600nF/6uF/60uF/600uF/6mF ±(4% + 5d),100mF ±(4% +10d) Temperature(C/F) -20℃~1000℃±(1% + 3d) -4℉~2372℉±(1% + 3d) Continuity Buzzer ≤30Ω , buzzer beeps Diode Test Y NCV Detection Y Data Hold Y LED Light Y LCD Backlight Y Analog Bar Y Low Battery Indication Y Low Battery Indication Y Accessories Test Lead, K-type thermocouple, Manual Power 1.5V AAA x 3pcs (Not Included)
The ABB S271 K1A is a 1-pole miniature circuit breaker from the System pro M S270 series, rated at 1 A with a K tripping characteristic. It provides thermal overload and magnetic short-circuit protection and supports 230/400 V AC operation with a 6 kA breaking capacity.
Fluke V3000 FC Wireless AC voltage module measures up to 1000 V true-RMS and logs data wirelessly using Fluke Connect for real-time sharing.
Fluke LVD2 CT Volt Light detects 90–600 V AC without contact, using dual-sensitivity LED indicators and an ultra-bright flashlight for safe voltage checks.