JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
Try searching for keywords in categories, brands, products, and more. If you have any questions, please contact our Support team
Out of stock
Shopping cart
Your cart is empty
Looks like you haven't made your choice yet.
x
SKU:
Subtotal:
Total:
My Quote
Your Quote is empty
Checkout using your account
This form is protected by reCAPTCHA - the Google Privacy Policy and Terms of Service apply.
Checkout as a new customer
Creating an account has many benefits:
CAT III 1000V Safety rating No contact AC voltage detection from 12 to 1000 VAC No metallic contact Compact size with pocket clip Red LED Voltage level indication Audible alarm if voltage is present Built-in white LED light
Fluke 289/FVF True-RMS industrial logging digital multimeter combo kit with TrendCapture and FlukeView Forms software. Features 100 kHz AC bandwidth, 10,000-reading logging, LoZ voltage, low pass filter, low ohm capability, and peak recording.
AEMC C.A 6117 Installation Tester Kit with RCD, loop, insulation & ground tests. Ideal for industrial environments with USB & DataView® software.
The Fluke 87V MAX E2 Kit offers a rugged true-RMS multimeter with an IP67 rating, 4 m drop protection, long battery life, and essential insulated accessories for industrial use.
Fluke SOL-TI-27HZKIT combines high-efficiency PV I-V curve tracing with 27 Hz thermography for fast, accurate solar performance testing.
Complies with CE safety standard 3 1/2 digits 1999 counts Palm size for easy storage and carrying Digits 3 1/2 digits 1999 counts Accuracy 0.5% best accuracy DCV 2200m/2000m/20/200V ±(0.8%+3d), 500V ±(1.0%+3d) ACV 200/500V ±(1.2%+5d) DCA 2000u/20m/200mA ±(1.2%+5d), 10A ±(2.5%+5d) ACA 400μA/4000μA ±(1.5%+10d), 40mA/400mA ±(1.5%+10d), 10A ±(2.5%+15d) Resistance 200Ω ±(1.5%+5d) , 2000/20k/200kΩ ±(1.0%+3d) , 20MΩ ±(1.0%+5d), 200MΩ ±(1.0%(rdg-l0)+10d) Temperature -40~150˚C ±(1.0%+3d), 150-1000˚C ±(1.5%+15d)-40~302˚F(1.0%+4d), 302-1832˚F ±(1.5%+15d) Power source 1.5V AAA x 2 (not included) Accessories Test leads Square signal output 50Hz (5 Vp-p, 50KΩ)
The Fluke IB875K kit pairs the rugged 87V True-RMS multimeter with insulated hand tools for safe, accurate industrial troubleshooting. It handles complex signals, VFD applications, and demanding environments while the included tools support high-voltage maintenance tasks.
AEMC 6424 Ground Resistance Tester Kit: 3-point testing with 150ft leads, auto-ranging, and large LCD—perfect for fast, accurate ground resistance measurement.
AEMC 4630 Ground Resistance Tester Kit with 500ft leads offers precise auto-ranging soil resistivity testing, rugged design, and rechargeable battery power.
AEMC 4620 Digital Ground Resistance Tester Kit 300ft: Rugged, auto-ranging earth ground and soil resistivity tester with high interference rejection for accurate results.
The Fluke 1587/I400 FC pairs a full-featured 2-in-1 insulation tester and True-RMS digital multimeter with a 400 A AC current clamp. Designed for maintenance, motor-drive, and electrical system diagnostics, it offers insulation resistance testing, voltage/current measurements, and clamp-based AC current readings in a single kit
AEMC 6472 Ground Resistance Tester Kit: Precision testing for soil resistivity, bond resistance, and earth potential with a 300ft (91.44m) cable and USB software support.
The Fluke 87V/PRV240 Digital Multimeter Kit combines the Fluke 87V Industrial Digital Multimeter with the PRV240 Proving Unit. The 87V supports AC/DC voltage and current measurement up to 1000 V and 10 A, resistance to 50 MΩ, capacitance, frequency to 200 kHz, and temperature from -200°C to 1090°C. The PRV240 provides a portable 240 V AC/DC source for verifying proper meter operation before testing.
The AEMC 6471 Ground Resistance Tester Kit with a 300ft cable is portable with a rechargeable battery, USB communication, auto-ranging, and accurate earth resistance measurement.
Schneider Electric S33595 Test Kit: Precision testing for STR & Micrologic trip units. 115/230V, ±5ms accuracy, 60W power. Reliable, efficient, and easy to use!
Schneider Electric S33595 Test Kit: Versatile 115/230V tool for Micrologic & STR trip units. Precise, reliable, and built for seamless circuit testing!
ACV True-RMS Auto Range Pocket Size 3-3/4 digits 3999 counts DCV 400mV, 4/40/400V ±(0.5%+4d), 600V ±(1%+4d) ACV 400mV±(1.5%+6d), 4/40/400V ±(0.8%+6d), 600V ±(1.0%+6d) Resistance 400Ω ±(0.8%+5d) 4k/40k/400k/4MΩ ±(0.8%+4d), 40MΩ ±(1.2%+5d) Frequency 100/1000Hz/10k/100k/1MHz/10MHz ±(0.5%+4d) Capacitance 4nF ±(5%+40d), 40n/400n/4μ/40μ ±(3.5%+8d), 2000μF ±(5%+8d) Duty cycle 0.1~99.9% ±(0.5%+4d) Continuity with beeper 50 ±30Ω Diode test Range: 0 ~ 1.5V Resolution: 1mV Power source 2 x 1.5V AAA battery (Not included)
The Pro’sKit 3 5/6-digit (5999 count) True-RMS flexible clamp meter delivers accurate AC current, resistance, and frequency measurements. Its flexible coil allows easy access around large conductors, while smart auto-ranging ensures precise, reliable readings in the field.
3 5/6 digits 5999 counts 0.5% best accuracy Dual display with analog bargraph Auto/Manual ranging USB data upload Measurement Range DC Voltage (DCV) 600m/6/60/600V ±(0.5%+4d), 1000V ±(1.0%+6d) AC Voltage (ACV) 6/60/600V ±(0.8%+10d), 750V ±(1.0%+10d) DC Current (DCA) 600μ/6000μA ±(1.0%+10d), 60m/600mA ±(1.0%+10d), 6/10A ±(1.2%+10d) AC Current (ACA) 600μ/6000μA ±(1.5%+10d), 60m/600mA ±(1.5%+10d), 6/10A ±(2.0%+15d) Resistance 600Ω ±(0.8%+5d), 6k/60k/600k/6MΩ ±(0.8%+4d), 60MΩ ±(1.2%+10d) Frequency 100/1000Hz ±(0.5%+4d), 10k/100kHz ±(0.5%+4d), 1M/30MHz ±(0.5%+4d) Capacitance 40nF±(5%+30d), 400n/4μ/40μF±(3.5%+8d) 200μF±(5.0%+10d) Temperature -20~400˚C(0~750˚F) ±(1.0%+5d), 400~1000˚C(750~1832˚F) ±(1.5%+15d) Continuity with Buzzer Yes Diode Test Yes Transistor Test Yes Power Source AAA(1.5V)×2pcs (Not included)
Full assortment of test functions Precise ACV ACA True RMS Measurements Overload Protection Non-contact voltage detection LCD Display 3-5/6 5999 Counts DCV 600mV/6V/60V/600V ±(0.5% +5d) ACV 600mV/6V/60V/600V ±(1% +4d) TRUE-RMS DCA 60mA/600mA ±(1.2% +5 d), 10A±(3.0% +5d) ACA 60mA/600mA ±(1.5% +5 d), 10A±(3.0% +5d)TRUE-RMS Frequency 9.999Hz/99.99Hz/999.9Hz/9.999KHz/99.99KHz/999.9KHz/9.999MHz ±(1.5% +5d) Duty Cycle 21%~99%±(2.5% +5 d) ResistanceΩ 600Ω/6k/60k/600k/6M/60MΩ ±(0.8% +5d) Capacitance 60nF/600nF/6uF/60uF/600uF/6mF ±(4% + 5d),100mF ±(4% +10d) Temperature(C/F) -20℃~1000℃±(1% + 3d) -4℉~2372℉±(1% + 3d) Continuity Buzzer ≤30Ω , buzzer beeps Diode Test Y NCV Detection Y Data Hold Y LED Light Y LCD Backlight Y Analog Bar Y Low Battery Indication Y Low Battery Indication Y Accessories Test Lead, K-type thermocouple, Manual Power 1.5V AAA x 3pcs (Not Included)
The AEMC 6471 Ground Resistance Tester Kit 500ft comes with a rechargeable battery, DataView software, and versatile 2- to 4-point earth resistance measurement.
Ensure precise testing and programming of ABB low voltage breakers with the ABB Sace PR010/T Protection Tester Kit! Portable, reliable, and easy to use.
The Megger DET4TCR2 Earth Resistance Tester with MCC1010 Current Clamp Kit delivers advanced ground testing capabilities, offering 2/3/4-point measurement, ART, and stakeless technology for precise electrical grounding and soil resistivity analysis.
Fluke FLK-V3000FC KIT enables wireless voltage and current monitoring with the 3000 FC multimeter and V3000 module, ideal for remote logging and safe diagnostics.
Fluke Wireless General Maintenance System: Fast, safe, and easy electrical panel testing with multi-module AC voltage and current measurements.