AEMC 4630 Ground Resistance Tester Kit with 500ft leads offers precise auto-ranging soil resistivity testing, rugged design, and rechargeable battery power.
AEMC 4620 Digital Ground Resistance Tester Kit 300ft: Rugged, auto-ranging earth ground and soil resistivity tester with high interference rejection for accurate results.
Fluke FLK-SMFT-1000/KIT PV analyzer and tester with I-V curve tracing, Auto Test Mode, IEC 62446-1 safety and performance checks for C&I solar systems.
350 pcs of 22 AWG solid wires Pre-cut, Pre-stripped and Pre-formed on each end. Variety of colors Completely Reusable 14 lengths x 25pcs each (2, 5, 7, 10, 12, 15, 17, 20, 22, 25, 50, 75, 100 and 125mm)
The Fluke 87V/E2 CAL Industrial Electrician Combo Kit centers on the Fluke 87V true-RMS digital multimeter and includes essential accessories for industrial electrical measurement. This configuration includes NIST traceable calibration with data and supports AC/DC voltage to 1000 V, AC/DC current to 10 A, resistance to 50 MΩ, capacitance to 9999 µF, frequency to 200 kHz, and temperature to 1090°C. Rated to CAT III 1000 V and CAT IV 600 V.
The AEMC 6471 Ground Resistance Tester Kit 500ft comes with a rechargeable battery, DataView software, and versatile 2- to 4-point earth resistance measurement.
Ensure precise testing and programming of ABB low voltage breakers with the ABB Sace PR010/T Protection Tester Kit! Portable, reliable, and easy to use.
Fluke SOL-TI-27HZKIT combines high-efficiency PV I-V curve tracing with 27 Hz thermography for fast, accurate solar performance testing.
3-1/2 digits 1999 counts 0.8% best accuracy Portable one-hand operation Data hold, low battery indication Max. jaw opening: 2 in.
LED & HFE test Null DCV Capacitance measurement Overload protection Multi-Function Digital Multimeter Specifications Function Measurement Range DCV 0.1/2.5/10/50/250V, 1000V Null DCV DC ±5V/±25V ACV 10/50/250V, 1000V DCA 50μ/2.5m/25m/250mA, 10A Resistance ×1(0.2~2kΩ)/ ×10(2~20kΩ)/ ×100(20~200kΩ)/ ×1k(200~2MΩ)/ ×10kΩ(2k~20MΩ) Capacitance C(R×1k): 2000μF(Approx.) Max Battery Check 1.5V/9V, Product does not contain batteries Transistor hFE Test Yes Diode & LED Test Yes Continuity with Beeper Yes Front Panel Controls Range selector switch with “OFF” position, 0Ω adjust knob Power Source AAA(1.5V) x 2pcs and 9-Volt x 1pcs
Model No. MT-1210 Digits 3-1/2 digits 1999 counts Accuracy 1.0% best accuracy DCV 200mV/2V/20V/200V ±(1.0%+2d)500V ±(1.2%+5d) ACV 200/500V ±(2.5%+10d) DCA 200μ/2mA/20mA/200mA ±(2.0%+5d) 10A ±(3.0%+5d) Resistance 200Ω/2K/20K/200KΩ ±(1.0%+5d) 2MΩ ±(1.5%+5d) Extra function
Complies with CE safety standard 3 1/2 digits 1999 counts Palm size for easy storage and carrying Digits 3 1/2 digits 1999 counts Accuracy 0.5% best accuracy DCV 2200m/2000m/20/200V ±(0.8%+3d), 500V ±(1.0%+3d) ACV 200/500V ±(1.2%+5d) DCA 2000u/20m/200mA ±(1.2%+5d), 10A ±(2.5%+5d) ACA 400μA/4000μA ±(1.5%+10d), 40mA/400mA ±(1.5%+10d), 10A ±(2.5%+15d) Resistance 200Ω ±(1.5%+5d) , 2000/20k/200kΩ ±(1.0%+3d) , 20MΩ ±(1.0%+5d), 200MΩ ±(1.0%(rdg-l0)+10d) Temperature -40~150˚C ±(1.0%+3d), 150-1000˚C ±(1.5%+15d)-40~302˚F(1.0%+4d), 302-1832˚F ±(1.5%+15d) Power source 1.5V AAA x 2 (not included) Accessories Test leads Square signal output 50Hz (5 Vp-p, 50KΩ)
Fluke 1587 MDT FC kit combines insulation testing, True-RMS multimeter functions, AC current measurement, and phase rotation checks for advanced motor diagnostics.
Fluke FLK-3000FC HVAC kit offers wireless multimeter and clamp measurements, remote monitoring, and logging for fast HVAC troubleshooting and safer testing.
3 5/6 digits 5999 counts 0.5% best accuracy Dual display with analog bargraph Auto/Manual ranging USB data upload Measurement Range DC Voltage (DCV) 600m/6/60/600V ±(0.5%+4d), 1000V ±(1.0%+6d) AC Voltage (ACV) 6/60/600V ±(0.8%+10d), 750V ±(1.0%+10d) DC Current (DCA) 600μ/6000μA ±(1.0%+10d), 60m/600mA ±(1.0%+10d), 6/10A ±(1.2%+10d) AC Current (ACA) 600μ/6000μA ±(1.5%+10d), 60m/600mA ±(1.5%+10d), 6/10A ±(2.0%+15d) Resistance 600Ω ±(0.8%+5d), 6k/60k/600k/6MΩ ±(0.8%+4d), 60MΩ ±(1.2%+10d) Frequency 100/1000Hz ±(0.5%+4d), 10k/100kHz ±(0.5%+4d), 1M/30MHz ±(0.5%+4d) Capacitance 40nF±(5%+30d), 400n/4μ/40μF±(3.5%+8d) 200μF±(5.0%+10d) Temperature -20~400˚C(0~750˚F) ±(1.0%+5d), 400~1000˚C(750~1832˚F) ±(1.5%+15d) Continuity with Buzzer Yes Diode Test Yes Transistor Test Yes Power Source AAA(1.5V)×2pcs (Not included)
Full assortment of test functions Precise ACV ACA True RMS Measurements Overload Protection Non-contact voltage detection LCD Display 3-5/6 5999 Counts DCV 600mV/6V/60V/600V ±(0.5% +5d) ACV 600mV/6V/60V/600V ±(1% +4d) TRUE-RMS DCA 60mA/600mA ±(1.2% +5 d), 10A±(3.0% +5d) ACA 60mA/600mA ±(1.5% +5 d), 10A±(3.0% +5d)TRUE-RMS Frequency 9.999Hz/99.99Hz/999.9Hz/9.999KHz/99.99KHz/999.9KHz/9.999MHz ±(1.5% +5d) Duty Cycle 21%~99%±(2.5% +5 d) ResistanceΩ 600Ω/6k/60k/600k/6M/60MΩ ±(0.8% +5d) Capacitance 60nF/600nF/6uF/60uF/600uF/6mF ±(4% + 5d),100mF ±(4% +10d) Temperature(C/F) -20℃~1000℃±(1% + 3d) -4℉~2372℉±(1% + 3d) Continuity Buzzer ≤30Ω , buzzer beeps Diode Test Y NCV Detection Y Data Hold Y LED Light Y LCD Backlight Y Analog Bar Y Low Battery Indication Y Low Battery Indication Y Accessories Test Lead, K-type thermocouple, Manual Power 1.5V AAA x 3pcs (Not Included)
Built-in white LED illumination light Detect AC voltage 90~1000 VAC with no metal contact Compact size with clip fits into pockets or tool pouches Red LED and audible alarm if voltage is present Non-conductive outer surface to avoid high voltage shock Powered by two 1.5V AAA batteries (not included) CAT IV 1000V Safety rating
The Fluke 87V MAX Digital Multimeter Solar PV Lead Kit combines the IP67-rated 87V MAX True-RMS multimeter with Pomona PVLEAD1 MC4 solar PV connector test leads. Designed for electrical troubleshooting in harsh environments, it supports AC/DC voltage up to 1000 V, 10 A current, resistance, capacitance, frequency, and temperature measurements. The included MC4 to 4 mm leads enable direct voltage verification on photovoltaic arrays while maintaining IEC / EN 61010-031 compliance.
AEMC 6424 Digital Ground Resistance Tester Kit 300ft: Accurate 3-point ground testing with auto-ranging, backlit LCD, and easy hookup for reliable earth resistance.
AEMC 4630 Digital Ground Resistance Tester Kit: Rugged, accurate 0-2000Ω auto-ranging soil resistivity and ground testing with rechargeable NiMH battery.
Compact and lightweight pocket-size device LCD display Non-contact ACV detector LED flashlight Data hold Low battery indication DCV 4200mV/2V/20V/200V±(0.5%+3d) 600V±(0.8%+5d) ACV 2V/20V/200V±(0.8%+3d) 600V±(1.0%+5d) DCA 200μA/2000μA /20mA/200mA±(1.8%+5d) ACA 200μA/2000μA /20mA/200mA±(2.0%+5d) Resistance 200Ω/2kΩ/20kΩ/200kΩ/2MΩ±(1.0%+3d) 20MΩ±(1.2%+15d) Non contact ACV detector Y Diode test Y Continuity with beep Y Certificate RoHS, CE EN61010-1 CATIII 600V Battery 2x1.5V AAA
Schneider Electric S33595 v1.60 Full-Function Test Kit for PowerPact P/R and MasterPact NT/NW breakers with Micrologic/STR interface cable, and USB–Serial adapter for Modbus connection.
The Fluke 283FC/PV enables safe 1500 V solar testing with TRMS accuracy, wireless current measurement, MC4 test leads, and logging for PV system diagnostics.
Fluke 116/62 MAX+ kit combines an HVAC multimeter with microamp and temperature testing plus a rugged IR thermometer for fast, precise HVAC diagnostics.
The Fluke 117/PRV240 Digital Multimeter and Proving Unit Kit delivers reliable, professional-grade testing for electricians, technicians, and safety inspectors. Designed for “Test Before Touch” (TBT) verification, it ensures your tools are working correctly before exposure to live circuits—reducing shock risk and improving field safety.