AEMC AmpFlex Rogowski coil sensor with 24" flexible loop. Measures 300A and 3000A AC with dual 10mV/A and 1mV/A outputs. Ideal for tight spaces and irregular conductor shapes.
AEMC SR182 AC Current Probe: Works with 6471/6472 testers for selective or stakeless ground resistance testing. 40A range, 13ft (4m) lead with CA connector.
Megger S1-568 5kV Insulation Resistance Tester: Reliable, high-accuracy testing with 6-hour battery life. Ideal for utilities and technicians in demanding environments.
AEMC MA114 MiniFlex® 14" Rogowski Coil — Flexible AC Current Sensor for Tight Spaces, Measures Up to 3000A, CAT IV 600V Rated
AEMC AmpFlex® Rogowski coil sensor, 36" flexible design for tight spots. Measures up to 3000A AC with 1mV/A output—ideal for irregular conductor shapes.
AEMC AmpFlex® flexible Rogowski coil sensor, 48" length, measures AC current up to 3000A with 10mV/1mV per amp output for tight spaces.
AEMC AmpFlex flexible Rogowski coil sensor, 36" length, measures AC current up to 3000A with 10mV/1mV per amp output for tight spaces.
AEMC MR417 Probe: Dual range AC/DC hall effect probe for oscilloscopes, 40A/400A & 60A/600A, BNC output, USB/battery power, auto zero adjust.
Megger 5kV/10kV Insulation Tester: Reliable, high-precision testing for safe electrical systems. Includes lead sets and durable hard case for easy use and storage.
The Megger DLRO10 is a digital low resistance ohmmeter designed for use in the field or in the laboratory. This device is compact and portable, making it an ideal tool for testing low resistance connections and conductors.
Fluke 772 Clamp Meter: Effortless 4-20 mA signal measurement & sourcing without breaking the loop. Compact, precise, and built for reliable control testing!
ACV True-RMS Auto Range Pocket Size 3-3/4 digits 3999 counts DCV 400mV, 4/40/400V ±(0.5%+4d), 600V ±(1%+4d) ACV 400mV±(1.5%+6d), 4/40/400V ±(0.8%+6d), 600V ±(1.0%+6d) Resistance 400Ω ±(0.8%+5d) 4k/40k/400k/4MΩ ±(0.8%+4d), 40MΩ ±(1.2%+5d) Frequency 100/1000Hz/10k/100k/1MHz/10MHz ±(0.5%+4d) Capacitance 4nF ±(5%+40d), 40n/400n/4μ/40μ ±(3.5%+8d), 2000μF ±(5%+8d) Duty cycle 0.1~99.9% ±(0.5%+4d) Continuity with beeper 50 ±30Ω Diode test Range: 0 ~ 1.5V Resolution: 1mV Power source 2 x 1.5V AAA battery (Not included)
AEMC MR416 Dual Range Probe: Hall effect AC/DC probe with 40A/400A & 60A/600A ranges, 10mV/A & 1mV/A output, 4mm plugs, USB or battery powered.
The Megger MJÖLNER 200 is a portable micro-ohmmeter high current system integrated into a rugged hard case with on-board display and controls. The front panel provides DC+ and COM terminals, dedicated sense inputs, shunt output, current clamp input, and labeled interface ports for field testing configurations.
Megger MIT1025 Insulation Tester: Measure insulation resistance up to 10kV with advanced diagnostics. Fast, reliable, and built for high-performance testing.
Compact and lightweight pocket-size device LCD display Non-contact ACV detector LED flashlight Data hold Low battery indication DCV 4200mV/2V/20V/200V±(0.5%+3d) 600V±(0.8%+5d) ACV 2V/20V/200V±(0.8%+3d) 600V±(1.0%+5d) DCA 200μA/2000μA /20mA/200mA±(1.8%+5d) ACA 200μA/2000μA /20mA/200mA±(2.0%+5d) Resistance 200Ω/2kΩ/20kΩ/200kΩ/2MΩ±(1.0%+3d) 20MΩ±(1.2%+15d) Non contact ACV detector Y Diode test Y Continuity with beep Y Certificate RoHS, CE EN61010-1 CATIII 600V Battery 2x1.5V AAA
Megger PAT420 Electrical Tester: Reliable, high-performance testing for earth bond, insulation, and more. Perfect for safety with easy-to-read LCD display. Made for professionals.
Full assortment of test functions Precise ACV ACA True RMS Measurements Overload Protection Non-contact voltage detection LCD Display 3-5/6 5999 Counts DCV 600mV/6V/60V/600V ±(0.5% +5d) ACV 600mV/6V/60V/600V ±(1% +4d) TRUE-RMS DCA 60mA/600mA ±(1.2% +5 d), 10A±(3.0% +5d) ACA 60mA/600mA ±(1.5% +5 d), 10A±(3.0% +5d)TRUE-RMS Frequency 9.999Hz/99.99Hz/999.9Hz/9.999KHz/99.99KHz/999.9KHz/9.999MHz ±(1.5% +5d) Duty Cycle 21%~99%±(2.5% +5 d) ResistanceΩ 600Ω/6k/60k/600k/6M/60MΩ ±(0.8% +5d) Capacitance 60nF/600nF/6uF/60uF/600uF/6mF ±(4% + 5d),100mF ±(4% +10d) Temperature(C/F) -20℃~1000℃±(1% + 3d) -4℉~2372℉±(1% + 3d) Continuity Buzzer ≤30Ω , buzzer beeps Diode Test Y NCV Detection Y Data Hold Y LED Light Y LCD Backlight Y Analog Bar Y Low Battery Indication Y Low Battery Indication Y Accessories Test Lead, K-type thermocouple, Manual Power 1.5V AAA x 3pcs (Not Included)
Introducing the Fluke 1730 Three-Phase Electrical Energy Logger: Your key to unlocking energy efficiency. Easily measure, analyze, and optimize power consumption in industrial and commercial settings. Simplify energy audits, conduct load studies, and make informed decisions to reduce costs. Compact, user-friendly, and packed with advanced features.Â
3 1/2 digits 1999 counts Dual slope A/D conversion Large backlit LCD display
The Megger DET4TCR2 Earth Resistance Tester with MCC1010 Current Clamp Kit delivers advanced ground testing capabilities, offering 2/3/4-point measurement, ART, and stakeless technology for precise electrical grounding and soil resistivity analysis.
Boost energy efficiency with the Fluke 1735 Power Logger! Perfect for three-phase load studies & electrical troubleshooting. Learn more and optimize your systems today!Â