JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
Try searching for keywords in categories, brands, products, and more. If you have any questions, please contact our Support team
Out of stock
Shopping cart
Your cart is empty
Looks like you haven't made your choice yet.
x
SKU:
Subtotal:
Total:
My Quote
Your Quote is empty
Checkout using your account
This form is protected by reCAPTCHA - the Google Privacy Policy and Terms of Service apply.
Checkout as a new customer
Creating an account has many benefits:
Complies with CE safety standard 3 1/2 digits 1999 counts Palm size for easy storage and carrying Digits 3 1/2 digits 1999 counts Accuracy 0.5% best accuracy DCV 2200m/2000m/20/200V ±(0.8%+3d), 500V ±(1.0%+3d) ACV 200/500V ±(1.2%+5d) DCA 2000u/20m/200mA ±(1.2%+5d), 10A ±(2.5%+5d) ACA 400μA/4000μA ±(1.5%+10d), 40mA/400mA ±(1.5%+10d), 10A ±(2.5%+15d) Resistance 200Ω ±(1.5%+5d) , 2000/20k/200kΩ ±(1.0%+3d) , 20MΩ ±(1.0%+5d), 200MΩ ±(1.0%(rdg-l0)+10d) Temperature -40~150˚C ±(1.0%+3d), 150-1000˚C ±(1.5%+15d)-40~302˚F(1.0%+4d), 302-1832˚F ±(1.5%+15d) Power source 1.5V AAA x 2 (not included) Accessories Test leads Square signal output 50Hz (5 Vp-p, 50KΩ)
AEMC MR526 Dual Range Probe: AC/DC hall effect probe with 100A/1000A & 150A/1400A ranges, 10mV/A & 1mV/A output, 4mm banana plugs, USB or battery power.
3 5/6 digits 5999 counts 0.5% best accuracy Dual display with analog bargraph Auto/Manual ranging USB data upload Measurement Range DC Voltage (DCV) 600m/6/60/600V ±(0.5%+4d), 1000V ±(1.0%+6d) AC Voltage (ACV) 6/60/600V ±(0.8%+10d), 750V ±(1.0%+10d) DC Current (DCA) 600μ/6000μA ±(1.0%+10d), 60m/600mA ±(1.0%+10d), 6/10A ±(1.2%+10d) AC Current (ACA) 600μ/6000μA ±(1.5%+10d), 60m/600mA ±(1.5%+10d), 6/10A ±(2.0%+15d) Resistance 600Ω ±(0.8%+5d), 6k/60k/600k/6MΩ ±(0.8%+4d), 60MΩ ±(1.2%+10d) Frequency 100/1000Hz ±(0.5%+4d), 10k/100kHz ±(0.5%+4d), 1M/30MHz ±(0.5%+4d) Capacitance 40nF±(5%+30d), 400n/4μ/40μF±(3.5%+8d) 200μF±(5.0%+10d) Temperature -20~400˚C(0~750˚F) ±(1.0%+5d), 400~1000˚C(750~1832˚F) ±(1.5%+15d) Continuity with Buzzer Yes Diode Test Yes Transistor Test Yes Power Source AAA(1.5V)×2pcs (Not included)
AEMC LM103 AC Current Probe, 200A range, 1mV/A output, 5 ft lead with banana plugs, 48 Hz–10 kHz frequency, compatible with power analyzers & DMMs.
AEMC MR417 Probe: Dual range AC/DC hall effect probe for oscilloscopes, 40A/400A & 60A/600A, BNC output, USB/battery power, auto zero adjust.
Amprobe PK-110 kit includes a digital multimeter, GFCI socket tester, and non-contact voltage probe for safe residential voltage and wiring checks.
AEMC AC/DC Current Probe Model MR6292: Accurate Hall effect probe with hook jaws for BSG mode current measurements. No battery needed; powered by Model 6292.
Boost energy efficiency with the Fluke 1735 Power Logger! Perfect for three-phase load studies & electrical troubleshooting. Learn more and optimize your systems today!
AEMC MN375 AC Current Probe: Compact 10A range with hooked jaw, 100mV/A output, banana plug lead, UL approved for precise power and low-level current use.
Full assortment of test functions Precise ACV ACA True RMS Measurements Overload Protection Non-contact voltage detection LCD Display 3-5/6 5999 Counts DCV 600mV/6V/60V/600V ±(0.5% +5d) ACV 600mV/6V/60V/600V ±(1% +4d) TRUE-RMS DCA 60mA/600mA ±(1.2% +5 d), 10A±(3.0% +5d) ACA 60mA/600mA ±(1.5% +5 d), 10A±(3.0% +5d)TRUE-RMS Frequency 9.999Hz/99.99Hz/999.9Hz/9.999KHz/99.99KHz/999.9KHz/9.999MHz ±(1.5% +5d) Duty Cycle 21%~99%±(2.5% +5 d) ResistanceΩ 600Ω/6k/60k/600k/6M/60MΩ ±(0.8% +5d) Capacitance 60nF/600nF/6uF/60uF/600uF/6mF ±(4% + 5d),100mF ±(4% +10d) Temperature(C/F) -20℃~1000℃±(1% + 3d) -4℉~2372℉±(1% + 3d) Continuity Buzzer ≤30Ω , buzzer beeps Diode Test Y NCV Detection Y Data Hold Y LED Light Y LCD Backlight Y Analog Bar Y Low Battery Indication Y Low Battery Indication Y Accessories Test Lead, K-type thermocouple, Manual Power 1.5V AAA x 3pcs (Not Included)
AEMC 4000D-24 Digital FlexProbe® with a 24” sensor and 6ft lead offers TRMS AC current measurement up to 4000A, compact and easy for tight spaces.
AEMC MR415 Current Probe: AC/DC hall effect probe with 400AAC/600ADC range, 1mV/A output, 4mm banana plugs, auto zero, USB/battery power.
AEMC 6527 Digital Megohmmeter: Multi-range insulation and continuity tester with voltmeter, audible alerts, and lockable test button for field use.
AEMC 400D-24 Digital FlexProbe®: True RMS AC current tester with 24ft flexible sensor, 400A range, ideal for tight spaces and CAT IV 600V safety rating.
Fluke 87V IMSK Kit: True-RMS multimeter and AC current clamp for precise electrical testing, with temperature probe and CAT IV 600V safety rating.
AEMC SR759 AC current probe with selectable ranges (1A–1000A), mV/A output, 5 ft lead. High accuracy and sensitivity for power quality and low current use.
AEMC LM102 AC Current Probe, 200A range, 1mA/A output, 5 ft lead with banana plugs, 48 Hz–10 kHz frequency, ideal for power analyzers and DMMs.
The Fluke 1773 offers professional three-phase power quality logging with a full set of PQ measurements, ±8 kV transient capture, intuitive touchscreen interface and robust design for industrial environments.
ACV True-RMS Auto Range Pocket Size 3-3/4 digits 3999 counts DCV 400mV, 4/40/400V ±(0.5%+4d), 600V ±(1%+4d) ACV 400mV±(1.5%+6d), 4/40/400V ±(0.8%+6d), 600V ±(1.0%+6d) Resistance 400Ω ±(0.8%+5d) 4k/40k/400k/4MΩ ±(0.8%+4d), 40MΩ ±(1.2%+5d) Frequency 100/1000Hz/10k/100k/1MHz/10MHz ±(0.5%+4d) Capacitance 4nF ±(5%+40d), 40n/400n/4μ/40μ ±(3.5%+8d), 2000μF ±(5%+8d) Duty cycle 0.1~99.9% ±(0.5%+4d) Continuity with beeper 50 ±30Ω Diode test Range: 0 ~ 1.5V Resolution: 1mV Power source 2 x 1.5V AAA battery (Not included)
Compact and lightweight pocket-size device LCD display Non-contact ACV detector LED flashlight Data hold Low battery indication DCV 4200mV/2V/20V/200V±(0.5%+3d) 600V±(0.8%+5d) ACV 2V/20V/200V±(0.8%+3d) 600V±(1.0%+5d) DCA 200μA/2000μA /20mA/200mA±(1.8%+5d) ACA 200μA/2000μA /20mA/200mA±(2.0%+5d) Resistance 200Ω/2kΩ/20kΩ/200kΩ/2MΩ±(1.0%+3d) 20MΩ±(1.2%+15d) Non contact ACV detector Y Diode test Y Continuity with beep Y Certificate RoHS, CE EN61010-1 CATIII 600V Battery 2x1.5V AAA
The Fluke 1630-2 FC is a high-performance ground-loop/leakage clamp meter that enables non-intrusive testing of bonded grounding systems — no auxiliary stakes needed — with wireless logging and rugged construction for industrial use.
Fluke T5-1000 tester measures voltage, continuity, and current up to 100 A with OpenJaw design and Slim Reach probes for tight spaces.
AEMC SR752 AC current probe, 1000A range, 1mV/A output, 52mm jaw, 5 ft lead. Ideal for DMMs, loggers, power meters with low phase shift and wide frequency range.
High-accuracy AEMC SR604 AC current probe with 1000A range, low phase shift, 1mA/A output, 5 ft lead, ideal for DMMs, loggers, oscilloscopes, and power measurements.
Amprobe CT235A AC/DC clamp transforms high current up to 1000A into safe millivolt signals for precise measurements with meters and data loggers.