AEMC 6611 Phase & Motor Rotation Meter: Identify phase order, motor direction, and live/open phases on 3-phase systems. Ideal 6609 replacement.
Built-in white LED illumination light Detect AC voltage 90~1000 VAC with no metal contact Compact size with clip fits into pockets or tool pouches Red LED and audible alarm if voltage is present Non-conductive outer surface to avoid high voltage shock Powered by two 1.5V AAA batteries (not included) CAT IV 1000V Safety rating
CAT III 1000V Safety rating No contact AC voltage detection from 12 to 1000 VAC No metallic contact Compact size with pocket clip Red LED Voltage level indication Audible alarm if voltage is present Built-in white LED light
Fluke 1777 Analyzer: Handheld three-phase power quality logging with automatic measurements, high-speed transients capture, and Bluetooth/Wi-Fi connectivity.
Fluke T6-600: Measure AC voltage and current without test leads using FieldSense™. True RMS accuracy, backlit display, and compact design.
Complies with CE safety standard 3 1/2 digits 1999 counts Palm size for easy storage and carrying Digits 3 1/2 digits 1999 counts Accuracy 0.5% best accuracy DCV 2200m/2000m/20/200V ±(0.8%+3d), 500V ±(1.0%+3d) ACV 200/500V ±(1.2%+5d) DCA 2000u/20m/200mA ±(1.2%+5d), 10A ±(2.5%+5d) ACA 400μA/4000μA ±(1.5%+10d), 40mA/400mA ±(1.5%+10d), 10A ±(2.5%+15d) Resistance 200Ω ±(1.5%+5d) , 2000/20k/200kΩ ±(1.0%+3d) , 20MΩ ±(1.0%+5d), 200MΩ ±(1.0%(rdg-l0)+10d) Temperature -40~150˚C ±(1.0%+3d), 150-1000˚C ±(1.5%+15d)-40~302˚F(1.0%+4d), 302-1832˚F ±(1.5%+15d) Power source 1.5V AAA x 2 (not included) Accessories Test leads Square signal output 50Hz (5 Vp-p, 50KΩ)
Fluke LVD2 CT Volt Light detects 90–600 V AC without contact, using dual-sensitivity LED indicators and an ultra-bright flashlight for safe voltage checks.
Compact and lightweight pocket-size device LCD display Non-contact ACV detector LED flashlight Data hold Low battery indication DCV 4200mV/2V/20V/200V±(0.5%+3d) 600V±(0.8%+5d) ACV 2V/20V/200V±(0.8%+3d) 600V±(1.0%+5d) DCA 200μA/2000μA /20mA/200mA±(1.8%+5d) ACA 200μA/2000μA /20mA/200mA±(2.0%+5d) Resistance 200Ω/2kΩ/20kΩ/200kΩ/2MΩ±(1.0%+3d) 20MΩ±(1.2%+15d) Non contact ACV detector Y Diode test Y Continuity with beep Y Certificate RoHS, CE EN61010-1 CATIII 600V Battery 2x1.5V AAA
Full assortment of test functions Precise ACV ACA True RMS Measurements Overload Protection Non-contact voltage detection LCD Display 3-5/6 5999 Counts DCV 600mV/6V/60V/600V ±(0.5% +5d) ACV 600mV/6V/60V/600V ±(1% +4d) TRUE-RMS DCA 60mA/600mA ±(1.2% +5 d), 10A±(3.0% +5d) ACA 60mA/600mA ±(1.5% +5 d), 10A±(3.0% +5d)TRUE-RMS Frequency 9.999Hz/99.99Hz/999.9Hz/9.999KHz/99.99KHz/999.9KHz/9.999MHz ±(1.5% +5d) Duty Cycle 21%~99%±(2.5% +5 d) ResistanceΩ 600Ω/6k/60k/600k/6M/60MΩ ±(0.8% +5d) Capacitance 60nF/600nF/6uF/60uF/600uF/6mF ±(4% + 5d),100mF ±(4% +10d) Temperature(C/F) -20℃~1000℃±(1% + 3d) -4℉~2372℉±(1% + 3d) Continuity Buzzer ≤30Ω , buzzer beeps Diode Test Y NCV Detection Y Data Hold Y LED Light Y LCD Backlight Y Analog Bar Y Low Battery Indication Y Low Battery Indication Y Accessories Test Lead, K-type thermocouple, Manual Power 1.5V AAA x 3pcs (Not Included)
AEMC 5233 Digital Multimeter: TRMS accuracy, NCV safety, and versatile functions—engineered for pros in electrical, HVAC, and electronics testing.
Fluke i17XX-FLEX1500 24: Measure up to 1500A with ease! Flexible, durable, and perfect for accurate power logging. A must-have tool for precise energy analysis
AEMC 275HVD Non-Contact High Voltage Detector with a 240V to 275kV range, LED/buzzer alerts, and a manual self-test for safe live-line checks.
AEMC High-frequency flexible AC current probe with a 10" sensor, measuring 0.5A to 300A with 1% accuracy. Offers excellent frequency response up to 1MHz, low phase shift, and overload protection. Ideal for oscilloscopes with BNC input, power measurements, and confined spaces.
Portable AEMC MH60 AC/DC Current Probe, 100A range, 1MHz bandwidth, 10 mV/A output, rechargeable battery, BNC connector, compatible with any oscilloscope.
Introducing the Fluke 1730 Three-Phase Electrical Energy Logger: Your key to unlocking energy efficiency. Easily measure, analyze, and optimize power consumption in industrial and commercial settings. Simplify energy audits, conduct load studies, and make informed decisions to reduce costs. Compact, user-friendly, and packed with advanced features.
Diagnose with precision! The Fluke 124B Industrial ScopeMeter is a powerful 40 MHz handheld oscilloscope designed for efficient troubleshooting in industrial settings. Learn more and upgrade your toolkit today!