JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
Try searching for keywords in categories, brands, products, and more. If you have any questions, please contact our Support team
Out of stock
Shopping cart
Your cart is empty
Looks like you haven't made your choice yet.
x
SKU:
Subtotal:
Total:
My Quote
Your Quote is empty
Checkout using your account
This form is protected by reCAPTCHA - the Google Privacy Policy and Terms of Service apply.
Checkout as a new customer
Creating an account has many benefits:
Complies with CE safety standard 3 1/2 digits 1999 counts Palm size for easy storage and carrying Digits 3 1/2 digits 1999 counts Accuracy 0.5% best accuracy DCV 2200m/2000m/20/200V ±(0.8%+3d), 500V ±(1.0%+3d) ACV 200/500V ±(1.2%+5d) DCA 2000u/20m/200mA ±(1.2%+5d), 10A ±(2.5%+5d) ACA 400μA/4000μA ±(1.5%+10d), 40mA/400mA ±(1.5%+10d), 10A ±(2.5%+15d) Resistance 200Ω ±(1.5%+5d) , 2000/20k/200kΩ ±(1.0%+3d) , 20MΩ ±(1.0%+5d), 200MΩ ±(1.0%(rdg-l0)+10d) Temperature -40~150˚C ±(1.0%+3d), 150-1000˚C ±(1.5%+15d)-40~302˚F(1.0%+4d), 302-1832˚F ±(1.5%+15d) Power source 1.5V AAA x 2 (not included) Accessories Test leads Square signal output 50Hz (5 Vp-p, 50KΩ)
3 5/6 digits 5999 counts 0.5% best accuracy Dual display with analog bargraph Auto/Manual ranging USB data upload Measurement Range DC Voltage (DCV) 600m/6/60/600V ±(0.5%+4d), 1000V ±(1.0%+6d) AC Voltage (ACV) 6/60/600V ±(0.8%+10d), 750V ±(1.0%+10d) DC Current (DCA) 600μ/6000μA ±(1.0%+10d), 60m/600mA ±(1.0%+10d), 6/10A ±(1.2%+10d) AC Current (ACA) 600μ/6000μA ±(1.5%+10d), 60m/600mA ±(1.5%+10d), 6/10A ±(2.0%+15d) Resistance 600Ω ±(0.8%+5d), 6k/60k/600k/6MΩ ±(0.8%+4d), 60MΩ ±(1.2%+10d) Frequency 100/1000Hz ±(0.5%+4d), 10k/100kHz ±(0.5%+4d), 1M/30MHz ±(0.5%+4d) Capacitance 40nF±(5%+30d), 400n/4μ/40μF±(3.5%+8d) 200μF±(5.0%+10d) Temperature -20~400˚C(0~750˚F) ±(1.0%+5d), 400~1000˚C(750~1832˚F) ±(1.5%+15d) Continuity with Buzzer Yes Diode Test Yes Transistor Test Yes Power Source AAA(1.5V)×2pcs (Not included)
Amprobe PK-110 kit includes a digital multimeter, GFCI socket tester, and non-contact voltage probe for safe residential voltage and wiring checks.
Full assortment of test functions Precise ACV ACA True RMS Measurements Overload Protection Non-contact voltage detection LCD Display 3-5/6 5999 Counts DCV 600mV/6V/60V/600V ±(0.5% +5d) ACV 600mV/6V/60V/600V ±(1% +4d) TRUE-RMS DCA 60mA/600mA ±(1.2% +5 d), 10A±(3.0% +5d) ACA 60mA/600mA ±(1.5% +5 d), 10A±(3.0% +5d)TRUE-RMS Frequency 9.999Hz/99.99Hz/999.9Hz/9.999KHz/99.99KHz/999.9KHz/9.999MHz ±(1.5% +5d) Duty Cycle 21%~99%±(2.5% +5 d) ResistanceΩ 600Ω/6k/60k/600k/6M/60MΩ ±(0.8% +5d) Capacitance 60nF/600nF/6uF/60uF/600uF/6mF ±(4% + 5d),100mF ±(4% +10d) Temperature(C/F) -20℃~1000℃±(1% + 3d) -4℉~2372℉±(1% + 3d) Continuity Buzzer ≤30Ω , buzzer beeps Diode Test Y NCV Detection Y Data Hold Y LED Light Y LCD Backlight Y Analog Bar Y Low Battery Indication Y Low Battery Indication Y Accessories Test Lead, K-type thermocouple, Manual Power 1.5V AAA x 3pcs (Not Included)
Fluke 87V IMSK Kit: True-RMS multimeter and AC current clamp for precise electrical testing, with temperature probe and CAT IV 600V safety rating.
ACV True-RMS Auto Range Pocket Size 3-3/4 digits 3999 counts DCV 400mV, 4/40/400V ±(0.5%+4d), 600V ±(1%+4d) ACV 400mV±(1.5%+6d), 4/40/400V ±(0.8%+6d), 600V ±(1.0%+6d) Resistance 400Ω ±(0.8%+5d) 4k/40k/400k/4MΩ ±(0.8%+4d), 40MΩ ±(1.2%+5d) Frequency 100/1000Hz/10k/100k/1MHz/10MHz ±(0.5%+4d) Capacitance 4nF ±(5%+40d), 40n/400n/4μ/40μ ±(3.5%+8d), 2000μF ±(5%+8d) Duty cycle 0.1~99.9% ±(0.5%+4d) Continuity with beeper 50 ±30Ω Diode test Range: 0 ~ 1.5V Resolution: 1mV Power source 2 x 1.5V AAA battery (Not included)
Compact and lightweight pocket-size device LCD display Non-contact ACV detector LED flashlight Data hold Low battery indication DCV 4200mV/2V/20V/200V±(0.5%+3d) 600V±(0.8%+5d) ACV 2V/20V/200V±(0.8%+3d) 600V±(1.0%+5d) DCA 200μA/2000μA /20mA/200mA±(1.8%+5d) ACA 200μA/2000μA /20mA/200mA±(2.0%+5d) Resistance 200Ω/2kΩ/20kΩ/200kΩ/2MΩ±(1.0%+3d) 20MΩ±(1.2%+15d) Non contact ACV detector Y Diode test Y Continuity with beep Y Certificate RoHS, CE EN61010-1 CATIII 600V Battery 2x1.5V AAA
Fluke T5-1000 tester measures voltage, continuity, and current up to 100 A with OpenJaw design and Slim Reach probes for tight spaces.
Model No. MT-1210 Digits 3-1/2 digits 1999 counts Accuracy 1.0% best accuracy DCV 200mV/2V/20V/200V ±(1.0%+2d)500V ±(1.2%+5d) ACV 200/500V ±(2.5%+10d) DCA 200μ/2mA/20mA/200mA ±(2.0%+5d) 10A ±(3.0%+5d) Resistance 200Ω/2K/20K/200KΩ ±(1.0%+5d) 2MΩ ±(1.5%+5d) Extra function
3 1/2 digits 1999 counts Dual slope A/D conversion Large backlit LCD display
AEMC NC-1 Non-Contact AC Voltage Detector: Indoor use, detects 120-240VAC within 5mm, 600V CAT III safety rated with battery-powered operation.
LED & HFE test Null DCV Capacitance measurement Overload protection Multi-Function Digital Multimeter Specifications Function Measurement Range DCV 0.1/2.5/10/50/250V, 1000V Null DCV DC ±5V/±25V ACV 10/50/250V, 1000V DCA 50μ/2.5m/25m/250mA, 10A Resistance ×1(0.2~2kΩ)/ ×10(2~20kΩ)/ ×100(20~200kΩ)/ ×1k(200~2MΩ)/ ×10kΩ(2k~20MΩ) Capacitance C(R×1k): 2000μF(Approx.) Max Battery Check 1.5V/9V, Product does not contain batteries Transistor hFE Test Yes Diode & LED Test Yes Continuity with Beeper Yes Front Panel Controls Range selector switch with “OFF” position, 0Ω adjust knob Power Source AAA(1.5V) x 2pcs and 9-Volt x 1pcs
AEMC MTX 3292B-BT Multimeter: TRMS 100000-count with Bluetooth, USB, color LCD, IP67, and full AC/DC, temp, freq & continuity testing.
Compact size, similar to iPhone Autoranging function True-RMS measurement Overload protection Large LCD Includes test leads Display 3 5/6 DC Voltage (V) 6V/60V/600V ±(0.8%+5d) AC Voltage (V) True-RMS 6V/60V/600V ±(1.0%+5d) DC Current (A) 1000mA/10A ±(2.0%+5d) AC Current (A) True-RMS 1000mA/10A ±(2.0%+5d) Resistance (Ω) 600Ω/6K/60K/600K/6M/60MΩ ±(1.0%+5d) Capacitance 6nF/60nF/600nF/6μF/60μF/600μF/6mF/100mF ±(4.0%+5d) Temperature -4°F~986°F ±(3%+5d) / -20°C~530°C ±(3%+5d) Frequency 1000Hz/6KHz ±(2.0%+5d) Safety CATII 600V Battery 1.5V AAA x 2
Amprobe AMP-220 Clamp Meter delivers accurate 600A AC/DC measurements with True-RMS, Amp-Tip, backlit display, and non-contact voltage detection.
The Fluke 87V MAX E2 Kit offers a rugged true-RMS multimeter with an IP67 rating, 4 m drop protection, long battery life, and essential insulated accessories for industrial use.
Fluke 289 Multimeter: Capture up to 15,000 events with TrendCapture, zoom analysis, and remote sharing via Fluke Connect for complex troubleshooting.
FLUKE-88-5/A Kit: Complete automotive multimeter combo with RPM, temperature, and advanced diagnostics for professional vehicle troubleshooting.
The Fluke 87V MAX Digital Multimeter Solar PV Lead Kit combines the IP67-rated 87V MAX True-RMS multimeter with Pomona PVLEAD1 MC4 solar PV connector test leads. Designed for electrical troubleshooting in harsh environments, it supports AC/DC voltage up to 1000 V, 10 A current, resistance, capacitance, frequency, and temperature measurements. The included MC4 to 4 mm leads enable direct voltage verification on photovoltaic arrays while maintaining IEC / EN 61010-031 compliance.
Fluke 287 multimeter: High-accuracy electronics logging with TrendCapture, real-time graphing, and Fluke Connect® compatibility for advanced diagnostics.
Fluke 289 multimeter: True-RMS logging for industrial, electrical, and electromechanical systems with TrendCapture and remote Fluke Connect support.
Fluke 279FC/IFLEX thermal multimeter combines TRMS measurement with built-in thermal imaging, iFlex current capability, and wireless Fluke Connect reporting.
Fluke 113 multimeter offers fast low-impedance VCHEK testing with AC/DC voltage detection, continuity checks, a bright backlit display, and CAT IV 600 V safety rating.
AEMC MTX 3290 Multimeter: Waterproof TRMS meter for measuring voltage, current, resistance, temp & more. Rugged IP67 body, CAT IV safety, and 6000-count LCD display.
AEMC 5233 Digital Multimeter: TRMS accuracy, NCV safety, and versatile functions—engineered for pros in electrical, HVAC, and electronics testing.