JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
Try searching for keywords in categories, brands, products, and more. If you have any questions, please contact our Support team
Out of stock
Shopping cart
Your cart is empty
Looks like you haven't made your choice yet.
x
SKU:
Subtotal:
Total:
My Quote
Your Quote is empty
Checkout using your account
This form is protected by reCAPTCHA - the Google Privacy Policy and Terms of Service apply.
Checkout as a new customer
Creating an account has many benefits:
Fluke 87V/E2 multimeter kit delivers precise True-RMS testing for industrial electricians, with VFD accuracy, peak capture, and essential accessories.
Fluke FLK-A3001FC KIT delivers wireless multimeter and iFlex current measurement with logging, remote monitoring, and seamless Fluke Connect integration.
Fluke 116/323 KIT delivers HVAC multimeter and clamp meter performance with microamp testing, built-in thermometer, and True-RMS accuracy for fast diagnostics.
FLUKE-88-5/A Kit: Complete automotive multimeter combo with RPM, temperature, and advanced diagnostics for professional vehicle troubleshooting.
The Fluke 289/IMSK Industrial Multimeter Service Kit combines the Fluke 289 logging multimeter with the i400 400A AC current clamp. The 289 features TrendCapture logging, low ohm capability, LoZ voltage, and a low pass filter for accurate measurements on variable frequency drives and noisy systems. The included i400 clamp enables current measurement up to 400 A AC without breaking circuits.
The Fluke 87V/E2 CAL Industrial Electrician Combo Kit centers on the Fluke 87V true-RMS digital multimeter and includes essential accessories for industrial electrical measurement. This configuration includes NIST traceable calibration with data and supports AC/DC voltage to 1000 V, AC/DC current to 10 A, resistance to 50 MΩ, capacitance to 9999 µF, frequency to 200 kHz, and temperature to 1090°C. Rated to CAT III 1000 V and CAT IV 600 V.
Compact and lightweight pocket-size device LCD display Non-contact ACV detector LED flashlight Data hold Low battery indication DCV 4200mV/2V/20V/200V±(0.5%+3d) 600V±(0.8%+5d) ACV 2V/20V/200V±(0.8%+3d) 600V±(1.0%+5d) DCA 200μA/2000μA /20mA/200mA±(1.8%+5d) ACA 200μA/2000μA /20mA/200mA±(2.0%+5d) Resistance 200Ω/2kΩ/20kΩ/200kΩ/2MΩ±(1.0%+3d) 20MΩ±(1.2%+15d) Non contact ACV detector Y Diode test Y Continuity with beep Y Certificate RoHS, CE EN61010-1 CATIII 600V Battery 2x1.5V AAA
Amprobe PK-110 kit includes a digital multimeter, GFCI socket tester, and non-contact voltage probe for safe residential voltage and wiring checks.
Fluke FLK-3000FC HVAC kit offers wireless multimeter and clamp measurements, remote monitoring, and logging for fast HVAC troubleshooting and safer testing.
The Fluke 179 True-RMS Digital Multimeter Electronics Kit supports electrical and electronic troubleshooting with voltage, current, resistance, frequency, capacitance, continuity, diode, and temperature measurements. The kit includes SureGrip accessories, a magnetic hanger, and a soft carry case for organized field use.
Industrial multimeter service kit combining the Fluke 179 True-RMS digital multimeter and Fluke 323 True-RMS clamp meter. Designed for troubleshooting electrical and electronic systems, with voltage measurement up to 1000 V AC/DC and AC current measurement up to 400 A.
Fluke 87V IMSK Kit: True-RMS multimeter and AC current clamp for precise electrical testing, with temperature probe and CAT IV 600V safety rating.
LED & HFE test Null DCV Capacitance measurement Overload protection Multi-Function Digital Multimeter Specifications Function Measurement Range DCV 0.1/2.5/10/50/250V, 1000V Null DCV DC ±5V/±25V ACV 10/50/250V, 1000V DCA 50μ/2.5m/25m/250mA, 10A Resistance ×1(0.2~2kΩ)/ ×10(2~20kΩ)/ ×100(20~200kΩ)/ ×1k(200~2MΩ)/ ×10kΩ(2k~20MΩ) Capacitance C(R×1k): 2000μF(Approx.) Max Battery Check 1.5V/9V, Product does not contain batteries Transistor hFE Test Yes Diode & LED Test Yes Continuity with Beeper Yes Front Panel Controls Range selector switch with “OFF” position, 0Ω adjust knob Power Source AAA(1.5V) x 2pcs and 9-Volt x 1pcs
Model No. MT-1210 Digits 3-1/2 digits 1999 counts Accuracy 1.0% best accuracy DCV 200mV/2V/20V/200V ±(1.0%+2d)500V ±(1.2%+5d) ACV 200/500V ±(2.5%+10d) DCA 200μ/2mA/20mA/200mA ±(2.0%+5d) 10A ±(3.0%+5d) Resistance 200Ω/2K/20K/200KΩ ±(1.0%+5d) 2MΩ ±(1.5%+5d) Extra function
Fluke 116/62 MAX+ kit combines an HVAC multimeter with microamp and temperature testing plus a rugged IR thermometer for fast, precise HVAC diagnostics.
Fluke FLK-289/FVF/IR3000 kit combines advanced logging, wireless sharing via Fluke Connect, and TrendCapture analysis for diagnosing complex electrical issues.
Fluke BK120-107 kit combines a SmartTrace breaker finder and 107 pocket multimeter for fast circuit identification and everyday electrical troubleshooting.
Fluke 289/FVF True-RMS industrial logging digital multimeter combo kit with TrendCapture and FlukeView Forms software. Features 100 kHz AC bandwidth, 10,000-reading logging, LoZ voltage, low pass filter, low ohm capability, and peak recording.
The Fluke 87V MAX E2 Kit offers a rugged true-RMS multimeter with an IP67 rating, 4 m drop protection, long battery life, and essential insulated accessories for industrial use.
Complies with CE safety standard 3 1/2 digits 1999 counts Palm size for easy storage and carrying Digits 3 1/2 digits 1999 counts Accuracy 0.5% best accuracy DCV 2200m/2000m/20/200V ±(0.8%+3d), 500V ±(1.0%+3d) ACV 200/500V ±(1.2%+5d) DCA 2000u/20m/200mA ±(1.2%+5d), 10A ±(2.5%+5d) ACA 400μA/4000μA ±(1.5%+10d), 40mA/400mA ±(1.5%+10d), 10A ±(2.5%+15d) Resistance 200Ω ±(1.5%+5d) , 2000/20k/200kΩ ±(1.0%+3d) , 20MΩ ±(1.0%+5d), 200MΩ ±(1.0%(rdg-l0)+10d) Temperature -40~150˚C ±(1.0%+3d), 150-1000˚C ±(1.5%+15d)-40~302˚F(1.0%+4d), 302-1832˚F ±(1.5%+15d) Power source 1.5V AAA x 2 (not included) Accessories Test leads Square signal output 50Hz (5 Vp-p, 50KΩ)
The Fluke IB875K kit pairs the rugged 87V True-RMS multimeter with insulated hand tools for safe, accurate industrial troubleshooting. It handles complex signals, VFD applications, and demanding environments while the included tools support high-voltage maintenance tasks.
The Fluke 1587/I400 FC pairs a full-featured 2-in-1 insulation tester and True-RMS digital multimeter with a 400 A AC current clamp. Designed for maintenance, motor-drive, and electrical system diagnostics, it offers insulation resistance testing, voltage/current measurements, and clamp-based AC current readings in a single kit
The Fluke 87V/PRV240 Digital Multimeter Kit combines the Fluke 87V Industrial Digital Multimeter with the PRV240 Proving Unit. The 87V supports AC/DC voltage and current measurement up to 1000 V and 10 A, resistance to 50 MΩ, capacitance, frequency to 200 kHz, and temperature from -200°C to 1090°C. The PRV240 provides a portable 240 V AC/DC source for verifying proper meter operation before testing.
ACV True-RMS Auto Range Pocket Size 3-3/4 digits 3999 counts DCV 400mV, 4/40/400V ±(0.5%+4d), 600V ±(1%+4d) ACV 400mV±(1.5%+6d), 4/40/400V ±(0.8%+6d), 600V ±(1.0%+6d) Resistance 400Ω ±(0.8%+5d) 4k/40k/400k/4MΩ ±(0.8%+4d), 40MΩ ±(1.2%+5d) Frequency 100/1000Hz/10k/100k/1MHz/10MHz ±(0.5%+4d) Capacitance 4nF ±(5%+40d), 40n/400n/4μ/40μ ±(3.5%+8d), 2000μF ±(5%+8d) Duty cycle 0.1~99.9% ±(0.5%+4d) Continuity with beeper 50 ±30Ω Diode test Range: 0 ~ 1.5V Resolution: 1mV Power source 2 x 1.5V AAA battery (Not included)
3 5/6 digits 5999 counts 0.5% best accuracy Dual display with analog bargraph Auto/Manual ranging USB data upload Measurement Range DC Voltage (DCV) 600m/6/60/600V ±(0.5%+4d), 1000V ±(1.0%+6d) AC Voltage (ACV) 6/60/600V ±(0.8%+10d), 750V ±(1.0%+10d) DC Current (DCA) 600μ/6000μA ±(1.0%+10d), 60m/600mA ±(1.0%+10d), 6/10A ±(1.2%+10d) AC Current (ACA) 600μ/6000μA ±(1.5%+10d), 60m/600mA ±(1.5%+10d), 6/10A ±(2.0%+15d) Resistance 600Ω ±(0.8%+5d), 6k/60k/600k/6MΩ ±(0.8%+4d), 60MΩ ±(1.2%+10d) Frequency 100/1000Hz ±(0.5%+4d), 10k/100kHz ±(0.5%+4d), 1M/30MHz ±(0.5%+4d) Capacitance 40nF±(5%+30d), 400n/4μ/40μF±(3.5%+8d) 200μF±(5.0%+10d) Temperature -20~400˚C(0~750˚F) ±(1.0%+5d), 400~1000˚C(750~1832˚F) ±(1.5%+15d) Continuity with Buzzer Yes Diode Test Yes Transistor Test Yes Power Source AAA(1.5V)×2pcs (Not included)