The Allen-Bradley 1489-M1C020 is a 2 Amp, 1-pole UL489 listed miniature circuit breaker with a C trip curve. It features a thermal-magnetic trip unit for branch circuit protection and is designed for commercial and light industrial power distribution applications.
The NOARK Ex9S32A32A is a 3-pole thermal-magnetic manual motor starter with an adjustable 24–32A current setting range and Class 10 overload protection. Designed for motor branch circuit protection, it provides manual isolation, manual motor control, and short-circuit protection with rotary handle operation.
The Siemens B220 2-Pole breaker delivers reliable 20A thermal-magnetic protection for 120/240V systems, ideal for Siemens P1 panelboards and BL-series load centers.
Allen-Bradley 1492-CB1 H030 is a 3A, 1-pole DIN rail supplementary circuit breaker designed for control circuit protection, featuring an H-trip curve for highly inductive loads and compact panel integration.
The Ferraz Shawmut UltraSafe USCC2 P216489 is a 2-pole modular fuse holder rated for 30A and 600 VAC/VDC for Class CC fuses. Designed for DIN rail mounting, it features IP20 finger-safe protection, pressure plate terminals, and a 200 kA SCCR for industrial control panel applications.
Eaton WMZS1C15 delivers reliable 15A C-curve supplementary protection for control panels and industrial circuits, with DIN-rail mounting and UL1077 compliance.
Eaton WMZS2B20 delivers reliable 20A Type B supplementary protection for control circuits, offering fast trip performance, DIN-rail mounting, and UL1077 compliance.
Eaton WMZT3D15 offers reliable 15A D-curve DIN-rail protection for high-inrush loads, delivering UL 489 performance for industrial panels and branch circuits.
Square D FAL3600311M Mag-Gard motor circuit protector delivers magnetic-only short-circuit protection for motor control applications with a 3A rating, 3-pole design, 600VAC operation, and adjustable 8A to 28A trip setting.
Siemens Q350 50A breaker provides reliable 3-pole protection for Siemens/ITE load centers, offering durable thermal-magnetic performance with plug-in QP design.
Bussmann R25100-3CR provides reliable 3-pole Class R fuse protection with 100A, 250V capacity for industrial power circuits, offering safe, high-performance operation.
Siemens 3NA3 814 fuse link delivers reliable 35A NH000 gG protection for SENTRON systems, offering high-breaking capacity and clear front indication for safe operation.
The Eaton WMZS2C50 2-pole 50A Type C breaker offers reliable DIN-rail protection for moderate-inrush industrial loads, delivering resettable thermal-magnetic performance.
The Eaton H2006B-3 is a Freedom NEMA heater coil set designed for thermal overload protection in motor control applications. This Class 20 standard trip heater pack supports selectable full load current settings from 1.79A to 2.9A via dial positions A–D and is supplied as a factory-calibrated set of three elements.
The Allen-Bradley 1492-SP1C250 is a single-pole, 25 A supplementary circuit breaker with a Type C tripping characteristic. Designed for DIN rail mounting, it provides thermal-magnetic overcurrent protection for commercial and light industrial control circuits operating with inductive loads.
GE THQL32020 Q-Line breaker delivers reliable thermal-magnetic protection with quick-make/quick-break action and 3-pole 20A design for GE load centers.
Square D FAL34050 delivers 50A, 3-pole thermal-magnetic circuit protection for 480V electrical systems with unit-mount installation and line/load lug connections.
The Eaton Bussmann DFJ-30 is a 30A Class J high speed, current-limiting drive fuse designed to protect AC and DC drives and power semiconductor devices. Rated up to 600 Vac and 450 Vdc, it provides very low I²t let-through energy and high interrupting capacity for demanding industrial applications.
Allen-Bradley 1492-CB1-H100 is a 10A single-pole thermal-magnetic supplementary circuit breaker for control circuits, featuring H-trip protection for highly inductive loads and DIN rail mounting.
The MTL IOP32D is a DIN-rail mounted surge protection device designed to protect digital and analogue I/O circuits. It provides surge protection for two independent loops (four wires) using a hybrid protection circuit rated up to 20 kA. The device is suitable for industrial control and instrumentation applications and is certified for use in hazardous areas.
Allen-Bradley 140M-C2E-C20 motor protection circuit breaker delivers adjustable 14.5–20A thermal overload and fixed magnetic short-circuit protection for three-phase motors in IEC and UL applications.
Allen-Bradley 1492-CB1-H010 supplementary protector delivers 1-amp single-pole thermal-magnetic overcurrent protection for industrial control circuits using DIN rail mounting.
Allen-Bradley 1492-CB2 H 200 is a 2-pole DIN-rail supplementary circuit breaker designed for industrial control panels, providing reliable thermal-magnetic overcurrent protection with an H-curve trip characteristic.
Allen-Bradley 1492-FB3J60-L fuse holder provides secure Class J fuse mounting for control applications, supporting reliable protection in industrial systems.
Bussmann JP60030-3PR is a 3-pole Class J pyramid fuse block rated 30 A and 600 V for panel-mounted circuit protection using LPJ, DFJ, and JKS fuses in control and power distribution assemblies.