Fluke TPS VOLTPROBE 1K V voltage probe supports up to 1000 V measurements for Topas 2000 and Model 1760 power quality applications.
AEMC 2139.71 K-thermocouple with 4mm integrated adapter replaces models 401, 403, 601, 603, 607, 675, and 5217 for precise temperature measurement.
The Georg Fischer Signet 3-8510 is an integral-mount paddlewheel flow sensor designed for use in liquid flow measurement applications. This sensor is part of the GF Signet flow measurement platform and is intended for installation within compatible piping systems to generate a flow-proportional signal.
WAGO 750-402 digital input module delivers reliable 4-channel 24V signal acquisition with 3 ms filtering for WAGO 750/753 systems, ideal for industrial sensors.
The Signal Fire AI-5 is a core alignment, single fiber fusion splicer with 4 motors and an S07 cleaver. Fast 8s splice, 18s heat, portable and field ready.
Thermo Scientific Niton XL2 980 GOLDD XRF Analyzer (Manufacturer Refurbished) provides fast, accurate analysis of light and heavy metals. Featuring advanced GOLDD technology, it’s portable, durable, and cost-effective for industrial use.
Temperature range: -58°F ~ 1076°F (-50°C to 580°C) Emissivity adjustable: 0.10 to 1.00 Distance spot ratio: 16:1 Resolution: 0.1°C / 0.1°F Temperature Range -50°C~580°C(-58°F ~1076°F) Accuracy ±2°C or ±2%°C/td> Distance Spot Ratio 16:1 Emissivity 0.1~1.0 Laser class Class II ,
Eagle Eye HGD-SB sensor board for HGD-Series gas detectors. PCB assembly with integrated components for gas detection systems.
The Gould Modicon B803 is a discrete input PLC module for Modicon 800 Series controller platforms. It provides eight isolated 115 VAC input points used to translate field-level ON/OFF signals into logic states readable by the PLC CPU in industrial automation systems.
Fluke I30S current clamp enables accurate AC/DC current measurement using Hall Effect technology for safe, non-intrusive testing with scopes and meters.
Fluke 80PK-24 Air Probe: Type-K thermocouple for precise air and non-caustic gas temperature measurement from -40 to 816°C.
AEMC Banana (Female) to BNC (Male) adapter XM-BB, rated 600V CAT III, compatible with AmpFlex sensors, Models K100/K110, and SLII Data Loggers.
AEMC 2140.77 Line & Phase Power Supply Adapter enables line and phase power connections for AEMC 8333, 8335, and 8336 analyzers, supporting 110V–1000V and DC–440 Hz operation.
The Fluke 53-II B is a single input digital thermometer designed for contact temperature measurement using J, K, T, E, N, R, and S thermocouples. It logs up to 500 temperature readings at user-adjustable intervals and includes a real-time clock for time-stamped data review.
Fluke 417D/62MAX+ combines a laser distance meter and IR thermometer for HVAC layout, diagnostics, and electrical troubleshooting, delivering fast distance measurement and non-contact temperature readings.
The Telemotive E7150-1-B is a radio remote control receiver module used in industrial wireless control systems. It functions as the fixed receiving unit that interprets signals from a paired handheld transmitter to control machinery. The module operates as part of a Telemotive radio control system and includes diagnostic indicators for system monitoring and troubleshooting.
Fluke 80PK-22 immersion temperature probe delivers reliable Type-K measurements for liquids and gels. Designed for wide temperature ranges and fast response when used with compatible thermocouple instruments.
Fluke 80PK-9 Type-K general purpose temperature probe designed for surface, air, and non-caustic gas measurements, offering reliable contact sensing across a wide industrial temperature range.
Fluke Networks 10220101 is a 6-wire in-line modular adapter with K-Plug, designed for safe circuit access and line testing on active telephone networks without interrupting service.
Fluke 729 30G FC Automatic Pressure Calibrator generates and regulates pressure up to 300 psi, automates test procedures, and documents results.
Fluke Networks Electrical Contractor Telecom Kit I: Durable telecom tool kit with TS30 test set for installation, testing, and troubleshooting.
AEMC 2126.47 Flexible K Type Thermocouple: 1m length, -58 to 480°F (-50 to 248.889°C) range, designed for data loggers SLII L642 & CA863. Reliable temperature measurement.
The DSX CableAnalyzer Series offers a comprehensive copper test solution for certifying twisted pair cabling, supporting up to 40 Gigabit Ethernet deployments and compatible with various cable types such as Cat 5e, 6, 6A, 8, or Class FA/II. Cable certification is a critical step in the larger process of system deployment, and efficiency is key to profitability. Many factors can slow down this process, including tester setup errors, testing against incorrect limits, waiting for skilled technicians to troubleshoot issues, result misinterpretation, and producing unintelligible test reports.
The Olympus Omniscan OMNI-MX PA3211PR is a modular phased array ultrasonic flaw detector featuring Remote Control Interface, Multigroup Support, and optional TOFD (Time-of-Flight Diffraction) capability. Certified pre-owned and built for advanced NDT applications in aerospace, energy, and manufacturing environments, it delivers safe, flexible, and efficient inspection workflows.
The Fujikura 70S+ is the world’s fastest and most robust core alignment fusion splicer. A user-programmable, automated wind protector expedites the splicing process by automatically closing to initiate the splicing process and opening upon splice completion. Fully programmable “auto open sheath clamps” open one or both sheath clamps, after the tensile test, to prepare the fiber for removal. A new automated “clamshell design” tube heater applies heat to both sides of the splice protection sleeve resulting in a 13-second shrink time. The result is a total splice process time of approximately 21 seconds! Ruggedness and durability are greatly enhanced by a mirrorless optical system and a """"severe-impact resistant"""" monitor. Battery capacity is now 200 splices/shrinks.