JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
Try searching for keywords in categories, brands, products, and more. If you have any questions, please contact our Support team
Out of stock
Shopping cart
Your cart is empty
Looks like you haven't made your choice yet.
x
SKU:
Subtotal:
Total:
My Quote
Your Quote is empty
Checkout using your account
This form is protected by reCAPTCHA - the Google Privacy Policy and Terms of Service apply.
Checkout as a new customer
Creating an account has many benefits:
AEMC SR701 1000A AC Current Probe with 1mA/A output, 52mm jaw, low phase shift, and wide frequency response. Ideal for DMMs, loggers, and power meters.
The 750ADM Mk3, a compact and robust primary current injection system, delivers a formidable 750A output while maintaining a maximum voltage of 5V. This unit is perfect for low-power primary injection tasks demanding up to 750A for brief periods. For applications demanding higher currents and powers, we offer 7kVA and 20kVA primary injection systems. Additionally, our PCU1-SP and PCU2/E systems feature separate control and loading units, enabling versatile load condition coverage through various loading units.
Eagle Eye GD-3000 combustible gas detector with selectable methane, propane, or hydrogen detection, digital display, alarm buzzer, fan relay, alarm relay, and 4-20 mA output.
AEMC AC/DC Current Probe Model MR6292: Accurate Hall effect probe with hook jaws for BSG mode current measurements. No battery needed; powered by Model 6292.
AEMC SR752 AC current probe, 1000A range, 1mV/A output, 52mm jaw, 5 ft lead. Ideal for DMMs, loggers, power meters with low phase shift and wide frequency range.
AEMC MN375 AC Current Probe: Compact 10A range with hooked jaw, 100mV/A output, banana plug lead, UL approved for precise power and low-level current use.
The Buckleys Dry Roof Pro2 is a flat roof leak detector kit for testing a wide range of non-conductive roof coverings. It combines adjustable high-voltage output, precise sensitivity control, and a compact IP65-rated design for reliable leak detection in demanding environments.
AEMC SR759 AC current probe with selectable ranges (1A–1000A), mV/A output, 5 ft lead. High accuracy and sensitivity for power quality and low current use.
AEMC MR415 Current Probe: AC/DC hall effect probe with 400AAC/600ADC range, 1mV/A output, 4mm banana plugs, auto zero, USB/battery power.
Buckleys WRP01 Wet Roof Pro’ is a roof leak detector for locating faults in wet flat roofing membranes using voltage gradient measurement across non-conductive surfaces over conductive substrates.
Fluke 80PK-10 pipe clamp temperature probe enables fast, repeatable surface measurements on 1.25–2.5 in pipes using a Type-K thermocouple, ideal for superheat and HVAC diagnostics.
Phoenix Contact RAD-IN-4A-I analog input extension module with four 4–20 mA input channels. Designed for use with Phoenix Contact Radioline bidirectional wireless systems, this module acquires analog current signals and maps them to a corresponding output module via the internal bus.
Amprobe TMA10A anemometer measures air velocity, airflow, and temperature with a flexible vane, dual display, RS232 output, and multi-point averaging for HVAC diagnostics.
The Megger Sverker 750 Relay Test Set is the ultimate toolbox for engineers, featuring a logical control panel layout that is familiar to SVERKER 650 users, ensuring immediate usability. It offers a powerful measurement section capable of displaying time, voltage, current, Z, R, X, S, P, Q, phase angle, and cos, enhancing relay testing efficiency. The voltmeter doubles as a secondary ammeter for differential relay testing. With its clear and easy-to-read display, all measurements are conveniently presented. The Sverker 750 incorporates a versatile built-in current source, providing outputs ranging from 0-10A to 0-250V AC or 0-300V DC. Designed to comply with EU and safety standards, it includes a serial port for seamless communication with personal computers using the SVERKER Win software. In addition to its extensive range of single-phase relay testing applications, covering relays such as overcurrent, undercurrent, ground fault, directional overcurrent, overvoltage, undervoltage, and more, the Sverker 750 boasts a variety of extra features. These include excitation curve plotting, transformer ratio tests, burden measurement, impedance measurement, efficiency tests, polarity tests, injection with various modes, filtering for averaged readings, and off delay functionality for delayed generation shutdown after tripping.
OPM 5 is designed for measuring optical power in all network types and performing insertion loss measurements on multimode or single-mode fiber optic links. Automatic Wavelength Identification Significantly Increases EfficiencyThe standard Wave ID feature automatically detects and sets the receive wavelength(s), preventing setup and measurement errors (when used with OLS series light sources). It significantly increases efficiency and reduces technician errors—and saves testing time—by eliminating the need to test each wavelength individually.
Complies with CE safety standard 3 1/2 digits 1999 counts Palm size for easy storage and carrying Digits 3 1/2 digits 1999 counts Accuracy 0.5% best accuracy DCV 2200m/2000m/20/200V ±(0.8%+3d), 500V ±(1.0%+3d) ACV 200/500V ±(1.2%+5d) DCA 2000u/20m/200mA ±(1.2%+5d), 10A ±(2.5%+5d) ACA 400μA/4000μA ±(1.5%+10d), 40mA/400mA ±(1.5%+10d), 10A ±(2.5%+15d) Resistance 200Ω ±(1.5%+5d) , 2000/20k/200kΩ ±(1.0%+3d) , 20MΩ ±(1.0%+5d), 200MΩ ±(1.0%(rdg-l0)+10d) Temperature -40~150˚C ±(1.0%+3d), 150-1000˚C ±(1.5%+15d)-40~302˚F(1.0%+4d), 302-1832˚F ±(1.5%+15d) Power source 1.5V AAA x 2 (not included) Accessories Test leads Square signal output 50Hz (5 Vp-p, 50KΩ)
Megger MOM2 BD-59092 240 A micro-ohmmeter. Used, function-tested. Includes red and black Kelvin clamps, AC adapter, straps, and hard carrying case for contact resistance testing up to 240 A.
Combines soldering, desoldering, smoke absorption, tip cleaning, temperature control, and energy-saving functions in one benchtop unit. It includes both a soldering iron and a desoldering gun, giving users a single station for electronics assembly, repair, and component removal.
Amprobe LM-200LED LED Light Meter delivers accurate lux and foot-candle measurements using a remote cosine-corrected sensor. Designed for professional LED and visible light evaluation.
Introducing the OWON ODP3063: Your Ultimate Precision Power Supply Solution.
Elcometer 331 TH Deep Cover Concrete Covermeter & Half Cell Gauge for reinforced concrete surveys requiring rebar location, cover depth measurement, bar sizing, and TH linear/grid data logging.
AEMC C177A AC Current Probe: 5mA–200A range, 10,000:1 ratio, 6.5ft CA connector lead—designed for CA6116N & CA6117 installation testers.
Banner 17268A LM5 adds adjustable on-delay timing to Banner Multibeam sensors for stable detection, jam prevention, and reliable automation performance.
AEMC MA114 MiniFlex® 14" Rogowski Coil — Flexible AC Current Sensor for Tight Spaces, Measures Up to 3000A, CAT IV 600V Rated