JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
Try searching for keywords in categories, brands, products, and more. If you have any questions, please contact our Support team
Out of stock
Shopping cart
Your cart is empty
Looks like you haven't made your choice yet.
x
SKU:
Subtotal:
Total:
My Quote
Your Quote is empty
Checkout using your account
This form is protected by reCAPTCHA - the Google Privacy Policy and Terms of Service apply.
Checkout as a new customer
Creating an account has many benefits:
Get precise, non-contact color and luminance measurements with the portable Konica Minolta CS-100 Chroma Meter. Perfect for lighting, quality control, and research, it offers high accuracy and ease of use in any setting. Upgrade your measurement tools today!
The Allen-Bradley 1770-KFDG DeviceNet RS-232 Interface Module with 9.0 Volts DC and 1.0 Amp of current rating. It has an RS-232 communication port, a 9-Pin D-Shell RS-232 Connector, and a 9-Pin D-Shell RS-232 Null Modem Cable.
AEMC PEL 112 power and energy logger supports electrical monitoring, energy audits, diagnostics, and load studies across multiple power systems.
Lake Shore RIMF2V1 frequency-to-voltage converter brings encoder signal conversion into a compact control module with selectable V/RPM and PPR settings, 0/4-20 mA output, ±10V output, ±300V output, and relay output.
White-Rodgers H06E-24 delivers 24 in universal replacement thermocouple capability for gas pilot light control, with stainless steel construction and adapter fittings for most pilot burners.
Gripple GS12-10S5-R5-2P seismic restraint kit delivers a ready cable-bracing hardware set with 1/8 in x 10 ft cable, GS12 fasteners, standard end fittings, and retrofit structural eyelets.
Siemens 75D70550004 magnetic coil supports D.P. Model F contactor replacement with dual-voltage operation at 380–440V 50 Hz and 440–480V 60 Hz.
ABB 1SVR427032R0000 switch mode power supply delivers 24 VDC output at 2.5 A from a 100–240 VAC input, with adjustable output voltage from 24–28 VDC and 60 W max load capacity for control and industrial power applications.
The Siemens 75D73070C AC coil set of 2 offers clearly labeled 50/60 Hz voltage ranges and V/W terminal markings for starter and contactor replacement needs.
Philips 3534B5A0460A110A3 aluminum electrolytic capacitor offers 460–553 MFD capacitance with a 110–125 VAC, 50/60 Hz rating in a cylindrical can format for component replacement and parts matching.
Square D 2510KG1 manual switch delivers reliable 30A control for single-phase systems with a 2-pole toggle design and non-reversing operation in a compact NEMA 1 enclosure.
Cisco 700-01663-01-A0 cable manager holder clip helps organize rackmounted networking cables with a compact 1U-compatible design for cleaner routing and easier front-rack cable control.
Fisher 972-097-1000 stereo headphones for TW6 offer clear audio with individual volume controls and 1/4" jack. Reduce noise, improve signal clarity, and extend battery life for detecting and line tracing.
Fisher TW6-KIT is a pipe and cable locator kit for locating and tracing buried conductive utilities using inductive and conductive operating modes. The system operates at 81.92 kHz and includes a search handle, carrying case, and headphones.
The Fluke i1010 is an AC/DC current clamp designed for use with digital multimeters. It measures currents from 1 A up to 1000 A DC and up to 600 A AC using a Hall-effect sensor. The clamp outputs 1 mV per amp for direct reading on compatible meters.
The Mitsubishi CP30-BA 1-Pole 5A M-Curve Circuit Protector is a compact DIN-rail-mounted supplementary protector designed for low-capacity control circuits. It features a medium-speed hydraulic-magnetic tripping characteristic, 5 A current rating, and supports AC 250 V or DC 65 V operation in industrial control panels.
Fluke i200 AC current clamp enables accurate 0.5–200A AC measurements using a multimeter. Features 1 mA/A output, banana plug interface, and CAT III 600V safety for electrical testing.
The Siemens 3SU1400-1AA10-1BA0 is a SIRIUS ACT contact module with one normally open contact. It features screw terminals and a snap-on design for front plate mounting behind compatible actuators. Designed for industrial control and signaling applications requiring reliable signal switching.
The General Electric DS200DDTBG2ABB is an LCI Auxiliary I/O Terminal Board for GE Mark V Speedtronic gas and steam turbine control systems. It provides auxiliary signal termination, conditioning, and isolation for analog and digital I/O in high-voltage industrial control environments.
This CCC Series 4 temperature input module set includes one IOM TCW (I-1/201-2/200) and one EIOM TCW (E-1/202-3/200). Both modules are designed for 3-wire GDC RTD temperature inputs and chassis mounting within CCC Series 4 control systems.
The ABB Bailey IMASI02 is an Analog Slave Input module for the Infi 90 Process Management System. It converts analog field signals into digital data for processing by a Multi-Function Processor and interfaces up to fifteen process signals through a single MMU slot.
The Phoenix Contact RAD-ISM-900-XD-BUS is an OMNEX industrial wireless transceiver module operating in the 900 MHz ISM band. It supports bidirectional wireless transmission of digital and analog I/O signals and mounts on a DIN rail with an integrated bus foot for I/O expansion.
The Phoenix Contact RAD-OUT-4A-I is a four-channel analog output extension module providing 4–20 mA current outputs for bidirectional wireless systems. It maps signals received from a corresponding RAD-IN-4A-I input module and mounts on a TS35 DIN rail.
The Vickers by Danfoss 868982 is an AC solenoid coil with dual voltage ratings printed on the housing for 110V at 50 Hz and 120V at 60 Hz. The unit features an encapsulated black housing with a central armature bore and factory-installed flying leads terminated with ring connectors.
Fluke 787B ProcessMeter combines a safety-rated digital multimeter with mA loop calibrator functions, enabling accurate measurement, sourcing, and simulation for industrial current loop troubleshooting.