The Emerson Ovation 5X00070G04 is an analog input module used within the Ovation Distributed Control System. It is designed for millivolt-level signal acquisition and supports selectable ±20 mV, ±50 mV, and ±100 mV input ranges across eight analog input channels.
The Modicon AS-B875-002 is an 8-channel analog input module designed for use with Modicon 984 programmable controllers. It accepts either 1–5 V or 4–20 mA input signals and converts field analog signals into digital data for PLC processing.
The Honeywell 620-0088 Parallel Link Driver Module is a communication module for the Honeywell IPC 620 PLC system. It supports parallel data transfer between compatible IPC 620 processors and connected system components and is used within industrial control, communication, and monitoring architectures.
The Honeywell 620-0081 Highway Interface Module (HIM) is a communication module used to connect Honeywell IPC 620 series controllers with TDC 2000/3000 Distributed Control Systems. It supports Data Hiway communication at 1.25 Mbps and is designed for rack-mounted installation in IPC 620 systems.
Emerson Ovation 1C31132G01 is an analog output personality module designed for four-channel Ovation analog output subsystems, routing field signals for 0-5 V, 0-10 V, and 0-20 mA output configurations.
Westinghouse Emerson 5X00226G02 Ovation I/O Interface Module delivers rack-mounted digital signal interfacing for Ovation DCS platforms, supporting controller communication with field-connected sensors and actuators in industrial control environments.
Westinghouse Emerson 5X00241G01 Ovation Processor Module brings real-time Ovation DCS control, 64 MB memory, 24V DC operation, Ethernet/serial integration, redundancy support, and diagnostics into industrial automation workflows.
Allen-Bradley 1771-OFE2 is a PLC analog output module built for 1771 I/O systems, delivering four isolated current outputs, selectable scaling, and block transfer operation for industrial control applications.
AutomationDirect D2-08NA-1 is an 8-point AC input module for DL205 PLC systems with 80-132 VAC input range, 47-63 Hz operation, removable terminal connection, and logic-side status indication.
The Westinghouse 5X00070G33 delivers precise multi-channel voltage signal acquisition for Ovation DCS environments, supporting ±5V and ±10V inputs with isolated channels and high-resolution data capture for reliable industrial monitoring.
WAGO 750-452 Analog Input Module delivers reliable PLC current signal acquisition for WAGO 750 I/O nodes, enabling precise control in industrial automation.
Automation Direct D4-08B-1 DL405 8-slot I/O base delivers reliable panel-mounted rack support for DirectLOGIC 405 PLC systems needing flexible modular expansion.
Modicon AS-BDEP-210 115 VAC 8-channel input module with 1.8 kV isolation for 800 Series I/O and 984 PLC racks. Provides reliable ON/OFF detection from 80–132 VAC with fast 10 ms response for stable discrete monitoring in legacy Modicon systems.
Allen-Bradley 1746-IA16 Series B delivers reliable 16-point 120V AC input capability for SLC 500 systems, with optical isolation, LED status, and easy wiring.
The Phoenix Contact RAD-OUT-4A-I is a four-channel analog output extension module providing 4–20 mA current outputs for bidirectional wireless systems. It maps signals received from a corresponding RAD-IN-4A-I input module and mounts on a TS35 DIN rail.
Phoenix Contact RAD-IN-4A-I analog input extension module with four 4–20 mA input channels. Designed for use with Phoenix Contact Radioline bidirectional wireless systems, this module acquires analog current signals and maps them to a corresponding output module via the internal bus.
Allen-Bradley 2706-B21J16 DL20 two-line message display provides clear ASCII text output from a host controller using RS-232, RS-422, or parallel communication for industrial notification systems.
Emerson Ovation 5X00106G31 electronics module for Ovation DCS analog input. Provides 8 isolated 4–20 mA channels with per-channel HART transceivers for device communication. Supports signal acquisition between field devices and the controller.
The GE Fanuc Genius IC660BBA106 is a current-source analog input block with six input channels designed for the Genius I/O system. It operates on 115 VAC or 125 VDC and supports 4–20 mA current inputs for industrial analog signal acquisition.
Westinghouse Emerson 5X00070G34 is an Ovation analog input module. The front label identifies analog input ranges of ±20 mV, ±50 mV, and ±100 mV. Module only.
The Phoenix Contact RAD-ISM-900-XD-BUS is an OMNEX industrial wireless transceiver module operating in the 900 MHz ISM band. It supports bidirectional wireless transmission of digital and analog I/O signals and mounts on a DIN rail with an integrated bus foot for I/O expansion.
Phoenix Contact RAD-IN-8D is an 8-channel digital input extension module for the Radioline system. It accepts 5–30 V AC/DC signals, mounts on a 35 mm DIN rail, and connects via a bus foot connector for modular industrial automation signal acquisition.
Allen-Bradley 1772-SD2 remote I/O scanner enables PLC-2 processors to communicate with remote I/O racks, supporting up to 1792 I/O points with serial twinaxial connectivity and LED status indicators.
Allen-Bradley 1746-A7 SLC 500 7-slot modular chassis supporting 1746 processors, I/O, and specialty modules. Designed for scalable PLC systems with side-mounted 1746 power supplies.
Allen-Bradley 1769-ECR delivers reliable CompactLogix bus termination for 1769 I/O banks, ensuring proper system detection and stable FlexBus communication.