Meet the Fluke 1734 Three-Phase Energy Logger – your go-to tool for easy, accurate energy monitoring. Track voltage, current, power, and more with WiFi connectivity and real-time data via the Fluke Connect® app. Perfect for spotting energy waste and optimizing your facility’s efficiency. Ready to take control of your energy use?
comemso Combined Mini-Charger-Tester HW Rev3.4 delivers fast portable CCS and CHAdeMO EVSE checks with touchscreen control, EV simulation, live results, and stored reports.
LED & HFE test Null DCV Capacitance measurement Overload protection Multi-Function Digital Multimeter Specifications Function Measurement Range DCV 0.1/2.5/10/50/250V, 1000V Null DCV DC ±5V/±25V ACV 10/50/250V, 1000V DCA 50μ/2.5m/25m/250mA, 10A Resistance ×1(0.2~2kΩ)/ ×10(2~20kΩ)/ ×100(20~200kΩ)/ ×1k(200~2MΩ)/ ×10kΩ(2k~20MΩ) Capacitance C(R×1k): 2000μF(Approx.) Max Battery Check 1.5V/9V, Product does not contain batteries Transistor hFE Test Yes Diode & LED Test Yes Continuity with Beeper Yes Front Panel Controls Range selector switch with “OFF” position, 0Ω adjust knob Power Source AAA(1.5V) x 2pcs and 9-Volt x 1pcs
The Pro’sKit 3 3/4-digit (3999 count) AC/DC clamp multimeter provides precise voltage, current, resistance, frequency, and capacitance measurements. Designed for technicians, it combines clamp convenience with multimeter versatility for accurate electrical diagnostics.
3-1/2 digits 1999 counts 0.8% best accuracy Portable one-hand operation Data hold, low battery indication Max. jaw opening: 2 in.
Diagnose with precision! The Fluke 124B Industrial ScopeMeter is a powerful 40 MHz handheld oscilloscope designed for efficient troubleshooting in industrial settings. Learn more and upgrade your toolkit today!
AEMC C.A 773 Voltage Tester: LED and backlit display, voltage absence test from 12VAC-1000VAC, continuity, phase rotation, and stray voltage detection.
Model No. MT-1210 Digits 3-1/2 digits 1999 counts Accuracy 1.0% best accuracy DCV 200mV/2V/20V/200V ±(1.0%+2d)500V ±(1.2%+5d) ACV 200/500V ±(2.5%+10d) DCA 200μ/2mA/20mA/200mA ±(2.0%+5d) 10A ±(3.0%+5d) Resistance 200Ω/2K/20K/200KΩ ±(1.0%+5d) 2MΩ ±(1.5%+5d) Extra function
3 5/6 digits 5999 counts 0.5% best accuracy Dual display with analog bargraph Auto/Manual ranging USB data upload Measurement Range DC Voltage (DCV) 600m/6/60/600V ±(0.5%+4d), 1000V ±(1.0%+6d) AC Voltage (ACV) 6/60/600V ±(0.8%+10d), 750V ±(1.0%+10d) DC Current (DCA) 600μ/6000μA ±(1.0%+10d), 60m/600mA ±(1.0%+10d), 6/10A ±(1.2%+10d) AC Current (ACA) 600μ/6000μA ±(1.5%+10d), 60m/600mA ±(1.5%+10d), 6/10A ±(2.0%+15d) Resistance 600Ω ±(0.8%+5d), 6k/60k/600k/6MΩ ±(0.8%+4d), 60MΩ ±(1.2%+10d) Frequency 100/1000Hz ±(0.5%+4d), 10k/100kHz ±(0.5%+4d), 1M/30MHz ±(0.5%+4d) Capacitance 40nF±(5%+30d), 400n/4μ/40μF±(3.5%+8d) 200μF±(5.0%+10d) Temperature -20~400˚C(0~750˚F) ±(1.0%+5d), 400~1000˚C(750~1832˚F) ±(1.5%+15d) Continuity with Buzzer Yes Diode Test Yes Transistor Test Yes Power Source AAA(1.5V)×2pcs (Not included)
The INNO Instrument SPA3200 is a 3-channel digital power meter built for precise power consumption testing in R&D, automated assembly lines, and power test benches. It combines high measurement accuracy, a wide direct-input range, real-time waveform display, harmonic analysis, and internal data storage in a compact semi-rack design.
3 1/2 digits 1999 counts Dual slope A/D conversion Large backlit LCD display
Compact and lightweight pocket-size device LCD display Non-contact ACV detector LED flashlight Data hold Low battery indication DCV 4200mV/2V/20V/200V±(0.5%+3d) 600V±(0.8%+5d) ACV 2V/20V/200V±(0.8%+3d) 600V±(1.0%+5d) DCA 200μA/2000μA /20mA/200mA±(1.8%+5d) ACA 200μA/2000μA /20mA/200mA±(2.0%+5d) Resistance 200Ω/2kΩ/20kΩ/200kΩ/2MΩ±(1.0%+3d) 20MΩ±(1.2%+15d) Non contact ACV detector Y Diode test Y Continuity with beep Y Certificate RoHS, CE EN61010-1 CATIII 600V Battery 2x1.5V AAA
Fluke SOL-INS87-KIT delivers complete PV testing with I-V curve tracing up to 1500V, insulation testing, clamp measurements, and multimeter diagnostics.
Full assortment of test functions Precise ACV ACA True RMS Measurements Overload Protection Non-contact voltage detection LCD Display 3-5/6 5999 Counts DCV 600mV/6V/60V/600V ±(0.5% +5d) ACV 600mV/6V/60V/600V ±(1% +4d) TRUE-RMS DCA 60mA/600mA ±(1.2% +5 d), 10A±(3.0% +5d) ACA 60mA/600mA ±(1.5% +5 d), 10A±(3.0% +5d)TRUE-RMS Frequency 9.999Hz/99.99Hz/999.9Hz/9.999KHz/99.99KHz/999.9KHz/9.999MHz ±(1.5% +5d) Duty Cycle 21%~99%±(2.5% +5 d) ResistanceΩ 600Ω/6k/60k/600k/6M/60MΩ ±(0.8% +5d) Capacitance 60nF/600nF/6uF/60uF/600uF/6mF ±(4% + 5d),100mF ±(4% +10d) Temperature(C/F) -20℃~1000℃±(1% + 3d) -4℉~2372℉±(1% + 3d) Continuity Buzzer ≤30Ω , buzzer beeps Diode Test Y NCV Detection Y Data Hold Y LED Light Y LCD Backlight Y Analog Bar Y Low Battery Indication Y Low Battery Indication Y Accessories Test Lead, K-type thermocouple, Manual Power 1.5V AAA x 3pcs (Not Included)
Megger DLRO10 digital microhmmeter provides 10A low-resistance testing from 0.1 μΩ to 2000 Ω with Kelvin accuracy, automatic forward/reverse current, inductive mode, P-Type twist probes, 3m hook leads, and hard case.
Complies with CE safety standard 3 1/2 digits 1999 counts Palm size for easy storage and carrying Digits 3 1/2 digits 1999 counts Accuracy 0.5% best accuracy DCV 2200m/2000m/20/200V ±(0.8%+3d), 500V ±(1.0%+3d) ACV 200/500V ±(1.2%+5d) DCA 2000u/20m/200mA ±(1.2%+5d), 10A ±(2.5%+5d) ACA 400μA/4000μA ±(1.5%+10d), 40mA/400mA ±(1.5%+10d), 10A ±(2.5%+15d) Resistance 200Ω ±(1.5%+5d) , 2000/20k/200kΩ ±(1.0%+3d) , 20MΩ ±(1.0%+5d), 200MΩ ±(1.0%(rdg-l0)+10d) Temperature -40~150˚C ±(1.0%+3d), 150-1000˚C ±(1.5%+15d)-40~302˚F(1.0%+4d), 302-1832˚F ±(1.5%+15d) Power source 1.5V AAA x 2 (not included) Accessories Test leads Square signal output 50Hz (5 Vp-p, 50KΩ)