JavaScript seems to be disabled in your browser. For the best experience on our site, be sure to turn on Javascript in your browser.
Try searching for keywords in categories, brands, products, and more. If you have any questions, please contact our Support team
Out of stock
Shopping cart
Your cart is empty
Looks like you haven't made your choice yet.
x
SKU:
Subtotal:
Total:
My Quote
Your Quote is empty
Checkout using your account
This form is protected by reCAPTCHA - the Google Privacy Policy and Terms of Service apply.
Checkout as a new customer
Creating an account has many benefits:
Wohler Rotary Viper M10 delivers drill-powered duct and vent cleaning with flexible shaft navigation and reversible rotation to remove lint and debris efficiently across bends and offsets.
Sauermann SiCA 230-5NSH combustion gas analysis delivers measurement of O2, CO, NO, SO2, and H2S with advanced data logging, reporting, emissions calculations, and connectivity for residential, commercial, and industrial combustion applications.
Sauermann SICA 2305NDC Si-CA 230 Combustion Gas Analyzer delivers advanced 5-gas combustion analysis with O2, CO, NO, NO2, and CxHy measurement capabilities, automatic data logging, report generation, emissions calculations, and industrial-grade diagnostic performance.
The Sauermann SICA 2303NL Combustion Gas Analyzer delivers O2, CO, and Low NO measurement with advanced combustion diagnostics, wireless connectivity, automatic data logging, emissions calculations, and predictive maintenance tools for residential, commercial, and industrial combustion analysis.
The Sauermann SICA 2302 Si-CA 230 delivers combustion gas analysis with O2 and CO sensing, data logging, report creation, pump purge control, wireless/USB PC connectivity, and high-CO protection.
The Sauermann Si-CA 130 KIT 3AH combustion gas analyzer delivers O2, CO, and NO measurement with combustion efficiency calculations, draft and differential pressure testing, wireless reporting, and advanced combustion diagnostics for HVAC and burner performance analysis.
WOHLER A550 USA with NO/NO2 Sensor: Redefining Flue Gas Analysis
Measurement of air speed, temperature, and humidity Detection of air leaks Integrated flow averaging method for large ducts Automatic calculation of air flow Hold function Selectable units Backlight Input of duct dimensions MIN and MAX memory Tripod connector
Sauermann Si-CA 130 KIT 2BH combustion gas analysis delivers O2 and CO measurement, combustion efficiency calculations, draft and differential pressure testing, wireless reporting, and real-time analysis through mobile and PC software platforms.
The Sauermann Si-CA 130 Combustion Gas Analyzer Kit 2AS delivers combustion efficiency calculations, draft and differential pressure measurement, CO and Oâ‚‚ analysis, graphical data visualization, and wireless connectivity for combustion testing and emissions diagnostics.
Eagle Eye GD-3000 combustible gas detector with selectable methane, propane, or hydrogen detection, digital display, alarm buzzer, fan relay, alarm relay, and 4-20 mA output.
Fluke 116/62 MAX+ kit combines an HVAC multimeter with microamp and temperature testing plus a rugged IR thermometer for fast, precise HVAC diagnostics.
Sauermann Si-CA 030 KIT 2BH measures combustion gas, draft, differential pressure, temperature, O2, CO, and calculated CO2 for boiler, engine, and combustion emissions monitoring.
Eagle Eye HGD-2000 hydrogen gas detector monitors Hâ‚‚ buildup in battery rooms and facilities with relay outputs, LED alarms, and 24/7 operation.
Sauermann 27630 CO Sensor for Si-CA 230
The inclusion of the Sauermann Replacement Electrochemical CO Sensor in the Si-CA 030 model exemplifies the brand's unwavering commitment to excellence, dependability, and cutting-edge technology, demonstrating its dedication to providing efficient and sophisticated solutions.
The Sauermann NO Sensor (0-5000ppm) is an expertly engineered device tailored for the precise detection and measurement of nitrogen monoxide (NO) gas levels, spanning from 0 to 5000 parts per million (ppm).
The inclusion of the Sauermann H2S Sensor (0-500ppm) with the Si-CA 230 Upgrade board provides an all-in-one solution for thorough gas detection and environmental monitoring, giving users the capability to efficiently mitigate potential risks.
Wöhler VIS 350 Inspection Camera 6352 delivers pan-and-tilt visual inspection for drain pipes, ventilation lines, and exhaust pipes with a 100 ft push rod, removable 7 in. monitor, and distance-counting documentation workflow.
The inclusion of the Si-CA 230 Upgrade board enhances the intelligence of the Sauermann CxHy Hydrocarbon Sensor, providing a sophisticated solution for the detection and monitoring of hydrocarbon gases.
The Si-CA 230 upgraded board for the Sauermann NO2 Sensor (0-1000ppm) offers an advanced solution designed to monitor and control nitrogen dioxide gas concentrations. It provides precise measurements, effortless integration, and improved data analysis capabilities.
The Sauermann Low NO2 Sensor (0-100ppm) equipped with a Si-CA 230 Upgrade board is an indispensable instrument for individuals in need of accurate and dependable monitoring of NO2 gas across a broad range of concentrations.
Pitot Tube Type S Ranges
Sauermann has developed a Sample Conditioning Unit strategically positioned at the exit of the sampling probe, facilitating swift condensation and immediate separation of water from the gas. This design effectively minimizes the exposure of the target gases to the condensed moisture.
Pitot Tube Specifications