Allen-Bradley 100-C16D*10 motor contactor built for switching motor loads in industrial control systems, featuring a 110-120V AC coil, 3-pole power contacts, and 1 NO auxiliary contact for control circuit integration.
General Electric B4A82S1F1V1 Type SBM Switch delivers compact rotary cam control for industrial panels, combining panel-mounted operation, double-break contacts, and 600 VAC/VDC, 20 A continuous switching capability.
Omron CJ1W-PD025 PLC power supply unit brings 24 VDC input power to CJ-series control racks with 5.0 A at 5 VDC, 0.8 A at 24 VDC, and 25 W capacity for modular automation systems.
Bently Nevada 330102-00-30-05-02-00 is a 3300 XL 8 mm proximity probe with 3/8-24 UNF thread, armor, and 5.0 m total length for non-contact vibration and displacement measurement in rotating machinery systems.
Allen-Bradley 889N-F3HFC-6F is a Bulletin 889N 3-pin straight female QD cordset with ToughLink TPE jacket, 16 AWG stranded copper conductors, 600V rating, and 6 ft cable length.
Helwig Carbon H704 high-speed turbine carbon brush is built for turbo generator service, delivering low-friction electrical contact, balanced current distribution, and dependable performance at peripheral speeds up to 180 mph.
Cooper Bussmann MV055F1DAX100E is a 5.5kV full-range medium voltage fuse rated at 100A with 50 kA RMS symmetrical interrupting capacity for feeder circuit, switchgear, and transformer protection.
SOR 101RN-KK45-M4-C1A differential pressure switch with 10-75 PSID adjustable range, RN weathertight aluminum housing, KK DPDT switching element, M4 diaphragm and O-ring system, and C1A 1/4 in NPT(F) pressure port.
VIAVI 3Z-RFV-AAT-2000 antenna alignment tool streamlines antenna and microwave alignment with an integrated touchscreen, onboard camera, GPS/GLONASS positioning, and Bluetooth connectivity for field-ready deployment.
The Fluke 1775 is a three-phase power quality analyzer used for troubleshooting and logging on electrical systems. It connects with voltage leads and flexible current probes and guides setup with on-screen verification, allowing measurement, logging, and review through its integrated display.
Hubbell Killark ENY-4TM 1-1/4 in Duraloy iron explosion-proof sealing fitting with nipple for vertical or horizontal conduit in hazardous locations.
Sick DFS60B-BDPA10000 incremental encoder with 10,000 PPR resolution, 10 mm blind hollow shaft, programmable TTL/HTL output, and radial M23 12-pin male connector for industrial motion control.
Leviton CR20-I commercial-grade duplex receptacle rated 20A, 125V in NEMA 5-20R configuration. Ivory narrow-body design with side-wire termination and self-grounding clip. Qty 5.
Emerson Ovation 1C31189G31 Speed Detector Module for the Ovation DCS. This module monitors rotating equipment speed and converts sensor input into digital data for real-time control, monitoring, and diagnostics.
INNO Instrument SCTH1000 is a pass-through current sensor for DC 0–1000A and AC 1000Apeak measurement, with DC–300 kHz bandwidth, ±(0.05% of rdg + 15 μA) accuracy, DB9 interface, and ±15V to ±24V supply.
The Eagle Eye GFL-1000 Portable DC Ground Fault Locator identifies current leakage faults in DC systems up to 1000 V. It measures grounding resistance and distributed capacitance to locate faults while systems remain online.
Wöhler 4798 Power Supply provides charging and operating power for compatible Wöhler VIS 2xx and VIS 3xx inspection camera systems. The adapter accepts 100–240 V input and delivers regulated 18 V, 1.5 A output with a typical charging time of about 3 hours.
The INNO Instrument Li-ion 216 is a rechargeable lithium-ion battery pack designed for use with INNO Instrument Mini 2 series fiber optic test equipment, including the Mini 2 OTDR. The battery provides an output of 7.4V with a capacity of 4300mAh (31.82Wh) and installs directly into compatible INNO handheld instruments as a field-replaceable power source.
INNO Instrument OLL-500-652D-SC-UPC OTDR launch fiber reel provides a 500 m singlemode fiber link used with optical time domain reflectometers to stabilize launch conditions and support evaluation of fiber connections during installation, verification, and troubleshooting.
INNO Instrument FL-500-SC-APC is a 500 m singlemode OTDR launch fiber reel with SC/APC connectors designed to support fiber optic link testing. The launch fiber provides a buffer distance that allows Optical Time Domain Reflectometers to measure near-end connections and reflectance with improved visibility.
Fisher XLT-17 leak detector offers precise acoustic water leak detection with a sensitive Multi-Sensor, adjustable filters, LCD display, and headphone output for use on concrete, asphalt, turf, and soil.
The TRACO POWER TSP 090-124 is a 90W DIN-rail mounted industrial power supply providing a regulated 24VDC output at up to 3.75A. Designed for factory and control panel environments, it features universal 85–264VAC input, convection cooling, adjustable output voltage, DC-OK signaling, and integrated protection functions.
Fisher XLT30-C acoustic leak detector with Little Foot and hydrophonic probe delivers precision underground and in-building leak detection using advanced filtering and high-sensitivity audio monitoring.
Fisher TW82P-HC 82.175 kHz underground line tracer with passive power detection for locating buried pipes and cables. Digital depth, azimuth, and signal current display in weatherproof IP65 housing.
Fisher TW82P Digital Line Tracer 82.175 kHz utility locator for buried pipe and cable tracing. Features Passive Power Mode, automatic depth and current measurement, and conductive or inductive signal application.